Specifications
RX-Express
Page 5
I
PUMP PRIMING MODE
Connect the auxiliary pump line supplied with the unit to the
male coupler at the rear of the machine. Disconnect the
vacuum hose intake from the left side of the clear dome and
place the end of the auxiliary line up into the opening in the
dome. Using your hand to create a seal around the line, turn on
the vacuum and solution pumps until you see water coming out
of the hose.
EMPTY MODE
Connect the auxiliary pump line to the male
coupler at the rear of the machine and place the
A! A+
oth& end into a drain. Turn on the solution switch
and allow the remaining water to be pumped free.
HEAD ASSEMBLY LEVEL (HEEL-TOE) ADJUSTMENT
/“k 1!
Roll the machine onto a flat, hard surface
and lower the head to its cleaning position.
From the side, at floor level, look to see if
the front and rear shoes on the cleaning
I
(
~u
head are making contact with the surface
simultaneously.
If the front shoe is off the
k
Fran!VaGShoe
Rem Sushing Adjustment
floor, the rear bushing must be loosened
and moved up.
If the rear shoe is off the
floor, the bushing must be adjusted down.
On the star wheel, two one-inch rubber plugs have been inserted into the plastic hub.
This is to increase the airflow of the electric vacuum motor and speed up drying time.
Remove the plugs when cleaning the star to prevent the buildup of debris in the hub.
CleanMaster Corporation 7/14/98