Specifications

RX-Express
Page 13
IMPORTANT
electrical parts.
Repair Guide
Make sure the machine is unplugged before the removal of any
Removal of Cleaning Head:
1. First, unscrew the head in the same direction it turns during
operation (or clockwise when looking from the underside).
2.
Once you have loosened the assembly, spin if off with your
hands. If the cleaning head is difficult to remove, you may
use a %“ socket wrench on the exposed center nut.
Replacing of Felt Seal:
A worn or “dried out” felt will not form a proper vacuum seal. This will impair the
extraction capabilities of the unit.
Therefore, the carpets are left more wet than is
desirable.
1. Remove cleaning head assembly.
2. Make sure felt is saturated with oil to insure a proper seal.
3. Remove and reverse seal so that ‘“new” face is against hub.
NOTE: Alternating sides will temporarily extend the life of the felt. However,
the seal may need to be replaced.
4. Reinstall head assembly.
NOTE: When reinstalling the head assembly, you should be able to “feel” the
felt compacting against the seal plate during the last quarter rotation of the
head.
Removal of Vacuum Motor:
1. Disconnect machine from power source.
2. Remove hose from end of vacuum motor.
3.
Remove 10-24 screws from side of frame.
4.
Lift motor.
5. Disconnect wires at terminal clips.
Removal and Re-installation of Solution Pump:
1. Disconnect machine from power source.
2.
Check that ail water has been evacuated from unit.
3. Disconnect ?4” hoses on either side of pump.
4.
Remove four (4) 10-24 screws and nuts mounting pump to side of frame.
5. Disconnect wires at wire nuts.
CleanMaster Corporation
7/18/95