Installation Manual

WWW.CLEANCOMFORT.COM
2
IO-UC36D16-24BIO-UC36D16-24B
DUCT OR SUPPLY SIDE INSTALLATION
A
A. Duct or Supply Side Coil Installation
1) Aach lamp socket to magnec bracket
with screws provided
4) Insert reector tabs (2) into holes in
magnec bracket
CLICK!
B
3) Gently press lamp down and “click in” (see B)
2) Insert lamp on angle (see A)
Install and Mount UV Coil PurierSafety Considerations
i
WARNING!
Power supply can cause electrical shock. Disconnect
power before installaon.
i
WARNING!
Ultraviolet light can be harmful to eyes & skin. Do not
look at the lamps when illuminated or powered.
To reduce the risk of UV exposure to skin and eyes,
only power the lamps when the installaon is complete.
Proprietary Notice
This document and the informaon disclosed herein
are proprietary data of Daikin North America LLC.
Neither this document nor the informaon contained
herein shall be reproduced, used, or disclosed to
others without the wrien authorizaon of
Daikin North America LLC except to the extent
required for installaon or maintenance of
recipients equipment.
Liability Notice
Daikin North America LLC does not accept any liability
for damage due to installaons of UV puricaon
equipment installed by unqualied personnel or the use
of parts/components/equipment that are not authorized
or approved by Daikin.
Copyright Notice
Copyright 2014, Daikin North America LLC
All rights reserved.
i
CAUTION!
Keep lamp surfaces clean. Lamps may contain small
amounts of mercury. If lamp breakage occurs clean
area and dispose with care.
i
CAUTION!
Ultraviolet light may aect plascs in the heang &
cooling system. Select a locaon that reduces lamp
exposure to plasc components that are not
UV resistant.
i
CAUTION!
Do not touch lamp glass without gloves. Keep lamp
surfaces clean.