Specifications
Clean Comfort HE Series – Evaporave Humidier Model HE18
2 www.cleancomfort.com SS-HE18-B
Our connuing commitment to quality products may mean a change in specicaons without noce.
© 2015 • • Houston, Texas • Printed in the USA.
Installation
Expected Humidity Performance Coverage
in Sq. Ft. Based on Construction Type
Humidier Performance Baseline Criteria
At Outside Temperature
Recommended
Setting
-20°F -29°C 15%
-10°F -23°C 20%
0°F -18°C 25%
10°F -12°C 30%
20°F -7°C 35%
30°F -1°C 40%
Model No. GPD Loose (0.75 AC/H) Average (0.50 AC/H) Tight (0.30 AC/H)
HE12 12 800 Sq. Ft. 1200 Sq. Ft. 2000 Sq. Ft.
HE17 17 1115 Sq. Ft. 1650 Sq. Ft. 2800 Sq. Ft.
HE18 18 1175 Sq. Ft. 1770 Sq. Ft. 3000 Sq. Ft.
Outside Design Temp. 0°F (-18°C)
Outside Design R.H. 70% R.H.
Inside Design Temp. 70°F (21°C)
Inside Design R.H. 30% R.H.
Air Changes / Hour (AC/H) 0.30
Ceiling Height 8 ft.
Furnace Plenum Temp. 120°F (49°C)
Furnace Run Time for Calculating Sq. Ft. 8 Hr. / Day
Vercal plenum surface of any forced air furnace