Specifications
www.cleancomfort.com
SS-HE12-B
12/15
WIRE JUMPER
(HOT)
115v.
60CY.
ON-OFF SWITCH
COMMON LEAD
FURNACE
C
HI
LO
GA50
CURRENT
SENSING
RELAY
MULTI
SPEED
BLOWER
MOTOR
AC L
AC N
HUM
24V. SOLENOID VALVE
727-58 24 V. TRANSFORMER
(HOT)
C
115v.
60CY.
ON-OFF SWITCH
AC L
AC N
HUM
SNSR
24V. SOLENOID VALVE
24 V. TRANSFORMER
L1
C
NO
(HOT)
L2
115v.
60CY.
ON-OFF SWITCH
HEP-12500 AIR
PRESSURE SWITCH
AC L
AC N
HUM
SNSRSNSR
SNSR
24V. SOLENOID VALVE
24 V. TRANSFORMER
R
FURNACE
CONTROL BOARD
C
24v.
60CY.
AC L
AC N
HUM
24V. SOLENOID VALVE
FURNACE
BOARD
W
WIRE JUMPER
OUTDOOR TEMP. SENSOR
OUTDOOR TEMP. SENSOR
OUTDOOR TEMP. SENSOR
OUTDOOR TEMP. SENSOR
N
W
24v.
60CY.
ACC
EAC
(HOT)
C
115v.
60CY.
ON-OFF SWITCH
COMMON LEAD
FURNACE
C
HI
LO
GA50
CURRENT
SENSING
RELAY
MULTI
SPEED
BLOWER
MOTOR
24V. SOLENOID VALVE
HUMIDISTAT
24 V. TRANSFORMER
(HOT)
C
115v.
60CY.
ON-OFF SWITCH
24V. SOLENOID VALVE
24V. SOLENOID VALVE
24 V. TRANSFORMER
L1
C
NO
(HOT)
L2
115v.
60CY.
ON-OFF SWITCH
HEP-12500 AIR
PRESSURE SWITCH
24 V. TRANSFORMER
HUM
FURNACE
CONTROL BOARD
C
24v.
60CY.
24V. SOLENOID VALVE
HUMIDISTAT
HUMIDISTAT
HUMIDISTAT
FURNACE
BOARD
WIRE
JUMPER
WIRE
JUMPER
WIRE
JUMPER
Specications:
• Model: HE12 (A & M) Evaporave Humidiers
• Type: Evaporave Flow Through
• Capacity: 12 Gallons Per Day
• Limited Warranty: 10 Years Parts*
• Replacement Evaporator Pad: HEP-GA10
(Replace 1-2 mes per season depending on water hardness
and condions in the home)
• Dimensions: 11⅞" W x 13⅜" H x 9½" D
• Weight: 7 Lbs.
• Home Size: To 2,000 Sq. Ft.
• Installaon: Warm Air / Return Air Plenum / Right or Le Side
• Plenum Opening: 8⅞" W x 9½" H
• Bypass Opening: 6"
• Pallet Qty: 30
• Cabinet Construcon: DuraPlast® Ultra-Violet Stable
Automove Grade Plasc
• Humidistat: “M” Models: HEP-MHX3C / “A” Models: HEP-GFX3 (Included)
• In Box: Humidier, Humidistat, Control Bypass Damper, 24VAC Transformer,
Solenoid Valve, Evaporator Pad, Saddle Valve, (HEP-GCV3412 Code Valve -
A Models), Installaon Instrucons, Template, Parts.
• Voltage: 24VAC
HEP-GFX3
Included
with "A" Models
HEP- MHX3C
Included
with "M" Models
TECHNICAL SUPPORT • 1-855-303-1821 • www.cleancomfort.com
Automatic Humidistat
7A-7D Electronic Humidistat
7A – To furnace control board 24VAC
7B – To constant power using 24VAC
transformer and pressure switch
7C – To furnace control board 115VAC
with 24VAC transformer
7D – To constant power using 24VAC relay
and current sensing relay
Manual Humidistat
7E-7H Manual Humidistat
7E – To furnace control board 24VAC
7F – To constant power using 24VAC
transformer and pressure switch
7G – To furnace control board 115VAC
with 24VAC transformer
7H – To constant power using 24VAC relay
and current sensing relay
7A
7E
7G
7H
7D
7F
7B
7C
13⅜" H
11⅞" W
9½" D
Evaporative Humidier
Model HE12
10 YEAR
ARTS
ED
Y
*
Y
Y
10 YEAR
PARTS
LIMITED
WARRANTY
*
* Complete warranty details available from your local
dealer or at www.cleancomfort.com
Descripon Part Number
Replacement evaporator
pad
HEP-GA10