Installation Manual
INSTALLING DUCT COLLARS
IO-DV090 IO-DV090
WWW.CLEANCOMFORT.COM
7
Aach three white plates
using three #8 screws
provided to create a 10" plug
Aach the 10" plug to rear
of the dehumidier using
six #8 screws
Aach the second 10" duct
collar as you did the rst.
Using six #8 screws provided.
90° Flow
Step 3. Choose desired orientaon for
10" diameter supply duct collar:
A. Straight through (180°) ow
B. Upward, out of the top (90°) ow
Remove the 10" circular knock out from top panel
of dehumidier using side cuers.
-OR-
Recycle three plates and nine extra screws.
These are only used for 90° ow opon
.
180° Flow
Aach the second 10" duct collar as you did the rst.
Use six #8 screws provided.
Ducting for Dehumidication
For the ideal installaon, draw air from the central part of
the home and return it to the isolated areas of the home
like the bedrooms, den, ulity room, or family room. Be
sure to ulize as many of these remote rooms as possible
and not just one locaon. The ductwork of the exisng
HVAC system can be used to supply air to the home. If
the exisng supply goes to isolated areas of the home,
discharge the supply from the DV090 into the supply duct
of the exisng HVAC system. If the exisng heang system
incorporates a central supply, installaon of a separate
supply duct from the DV090 to each isolated area is
recommended.