Installation Manual

SAFETY PRECAUTIONS
IO-DV090 IO-DV090
WWW.CLEANCOMFORT.COM
3
Safety Precautions
Read the installaon, operaon and maintenance instruc-
ons carefully before installing and operang this device.
Proper adherence to these instrucons is essenal to
obtain maximum benet from your DV090 Venlang
Dehumidier.
READ AND SAVE THESE INSTRUCTIONS
i
WARNING!
This symbol means important instrucons. Failure
to heed them can result in serious injury or death.
i
CAUTION!
This symbol means important instrucons.
Failure to heed them can result in injury or
material property damage.
Intended Application for DV090
Dehumidier
For the ideal installaon, draw air from the central part
of the home and return it to isolated areas of the home
like the bedrooms, den, ulity room, or family room. The
ductwork of the exisng heang system can be used to
supply dehumidied air to the home.
Registrations
The Clean Comfort DV090 conforms to UL STD 474 and
CSA Standard C22.2 No.92.
Specications
Part Number: DV090
Blower: 245 CFM @ 0.0" WG
220 CFM @ 0.4" WG
Power: 710 Was @ 80°F/60% RH
Supply Voltage: 110-120 Volt - 1 Phase - 60 Hz
Current Draw: 6.7 Amps
Energy Factor: 2.5 L/kWhr
Operating Temp.: 56 °F (13 °C) Min, 95°F (35 °C) Max
Sized For: Up to 2200 Sq. Ft. - Typical
Performance at 80° F/60% RH:
Capacity 90 Pints/Day (43 L/Day)
Eciency: 5.3 pints/kWhr (2.5 L/kWhr)
Duct Connections:
6" Round Inlet; 10" Round Inlet;
10" Round Outlet
Air Filter:
Eciency: MERV-11
Standard 65% Ecient
ASHRAE Dust Spot Test
Size: 14" X 14" x1"
Power Cord: 8 . (2.4 m)
Drain Connection: 3/4" Threaded FNPT
Refrigerant Type R410a (Refer to manufacturers
label for more informaon)
Dimensions: Unit Shipping
Width:
15½" (39 cm) 18½" (47 cm)
Height:
21" (53 cm) 21½" (54.6 cm)
Length:
33½" (85 cm) 40" (102 cm)
Weight:
92 lbs (42 kg) 102 lbs (46 kg)
Installation
i
CAUTION!
Prior to installaon of the DV090, the following
consideraons for selecng the locaon for this
equipment should be reviewed. The DV090 can
be installed in a variety of locaons to meet the
owner's needs, and integrate with exisng forced
air systems or exisng ductwork if desired.
The locaon choice is conngent on a variety of
requirements not limited to: ease of service,
controls access, drainage, ltraon, access to
power, fresh-air venlaon, water damage
prevenon and current regulatory codes
(ASHRAE, re, etc). Please address all of these
issues before you select the device's locaon.
Optional Parts List: DV090
Ventilating Dehumidier
Part No. Description
DVP-4034748 Digital Control
DVP-4034753 Digital Control with remote
DVP-4034733 14"x14"x1" MERV 11 lter for
DV090 dehumidier
DVP-4034737 6" Duct Damper, Motorized for
DV070, DV090 and DV155 dehumidiers
DVP-4034742 10" Backdra Gravity Damper for
DV090 and DV155 dehumidiers