Installation Manual
SAFETY PRECAUTIONS
IO-DV090 IO-DV090
WWW.CLEANCOMFORT.COM
3
Safety Precautions
Read the installaon, operaon and maintenance instruc-
ons carefully before installing and operang this device.
Proper adherence to these instrucons is essenal to
obtain maximum benet from your DV090 Venlang
Dehumidier.
READ AND SAVE THESE INSTRUCTIONS
i
WARNING!
This symbol means important instrucons. Failure
to heed them can result in serious injury or death.
i
CAUTION!
This symbol means important instrucons.
Failure to heed them can result in injury or
material property damage.
Intended Application for DV090
Dehumidier
For the ideal installaon, draw air from the central part
of the home and return it to isolated areas of the home
like the bedrooms, den, ulity room, or family room. The
ductwork of the exisng heang system can be used to
supply dehumidied air to the home.
Registrations
The Clean Comfort DV090 conforms to UL STD 474 and
CSA Standard C22.2 No.92.
Specications
Part Number: DV090
Blower: 245 CFM @ 0.0" WG
220 CFM @ 0.4" WG
Power: 710 Was @ 80°F/60% RH
Supply Voltage: 110-120 Volt - 1 Phase - 60 Hz
Current Draw: 6.7 Amps
Energy Factor: 2.5 L/kWhr
Operating Temp.: 56 °F (13 °C) Min, 95°F (35 °C) Max
Sized For: Up to 2200 Sq. Ft. - Typical
Performance at 80° F/60% RH:
Capacity 90 Pints/Day (43 L/Day)
Eciency: 5.3 pints/kWhr (2.5 L/kWhr)
Duct Connections:
6" Round Inlet; 10" Round Inlet;
10" Round Outlet
Air Filter:
Eciency: MERV-11
Standard 65% Ecient
ASHRAE Dust Spot Test
Size: 14" X 14" x1"
Power Cord: 8 . (2.4 m)
Drain Connection: 3/4" Threaded FNPT
Refrigerant Type R410a (Refer to manufacturers
label for more informaon)
Dimensions: Unit Shipping
Width:
15½" (39 cm) 18½" (47 cm)
Height:
21" (53 cm) 21½" (54.6 cm)
Length:
33½" (85 cm) 40" (102 cm)
Weight:
92 lbs (42 kg) 102 lbs (46 kg)
Installation
i
CAUTION!
Prior to installaon of the DV090, the following
consideraons for selecng the locaon for this
equipment should be reviewed. The DV090 can
be installed in a variety of locaons to meet the
owner's needs, and integrate with exisng forced
air systems or exisng ductwork if desired.
The locaon choice is conngent on a variety of
requirements not limited to: ease of service,
controls access, drainage, ltraon, access to
power, fresh-air venlaon, water damage
prevenon and current regulatory codes
(ASHRAE, re, etc). Please address all of these
issues before you select the device's locaon.
Optional Parts List: DV090
Ventilating Dehumidier
Part No. Description
DVP-4034748 Digital Control
DVP-4034753 Digital Control with remote
DVP-4034733 14"x14"x1" MERV 11 lter for
DV090 dehumidier
DVP-4034737 6" Duct Damper, Motorized for
DV070, DV090 and DV155 dehumidiers
DVP-4034742 10" Backdra Gravity Damper for
DV090 and DV155 dehumidiers