AE14-5 Series Installation Manual

FILTRATION
FILTRATION
WWW.CLEANCOMFORT.COM
7
IO-AE14-5
WIRING
Wiring
Wiring should only be performed by qualied personnel.
All wiring must comply with all applicable codes and
standards. The voltage of the power source must match
the voltage indicated on the air cleaner. The air cleaner
must operate ONLY when the system fan is running.
Make sure the air cleaner is properly grounded.
If the air cleaner is equipped with a cord and plug, the air
cleaner can be plugged into an outlet within 6 feet of the
unit. Do not use an extension cord if the outlet is too far
away. Have an electrician wire in a new outlet closer to
the air cleaner.
If the air cleaner is not equipped with a cord, then wire the
air cleaner directly to a power source, as indicated on the
rang label, preferably to the same source that is supplying
power to the furnace or air handler. The APS will power the
air cleaner when there is sucient airow to acvate the
sensor. See Figure 5.
Note: The ORANGE power switch will be lit even if there
is no airow.
This 120VAC air cleaner may only be wired to the EAC
contacts on the system module if these contacts carry
120 VAC power. Before wiring this air cleaner to the system
module, check the specicaons of the furnace or air
handler to ensure the system module has sucient unused
capacity to power this air cleaner with the fan operang in
all condions. The air cleaner uses approximately 30 Was
when operang. Some systems do not power the EAC
contacts on the system module on low speed.
System Check
Perform the following system check before operaon.
1. Replace prelters, collecng cells and carbon VOC
lters. Close the access door.
2. Turn air cleaner power switch ON. Ensure system
fan is operang. Both the power switch light and
performance indicator light should be lit. The power
switch light indicates the air cleaner has unit voltage.
The performance indicator light shows that the
air cleaner is operang.
Note: There may be some arcing or snapping sounds from
the collecng cells. This is normal when the unit is new.
In about two weeks, as the sharp edges of the cells become
smoother, the arcing will disappear.
Operation
The air cleaner will run as long as there is adequate airow
through the ducts. The air cleaner will not run if the system
fan is o.
To improve the performance of your air cleaner, these
simple steps are recommended:
3. Run your heang/cooling system fan connuously,
on low speed if available, since your air cleaner only
removes parculate maer when the system fan is
operang.
4. Ensure there are no obstrucons to airow (for
example, from furniture or carpets) in front of the
return air grilles so that air moves freely to the heang/
cooling equipment.
5. Check for proper operaon of the system fan.
Figure 6: Air Cleaner Schemac
(with Air-Proving Switch)