FILTRATION
FILTRATION
WWW.CLEANCOMFORT.COM
4
IO-AE14-5
SPECIFICATIONS
Table 1: Specicaons
Components
Cabinet: Constructed of heavy gauge galvanized steel
to resist corrosion and provide trouble-free installaon.
Holes are provided to facilitate mounng to the
ductwork or air handling equipment.
Power Box: Removable. Contains the power switch,
performance indicator light, safety interlock switch,
high-voltage power board, air-proving switch and
high-voltage contacts.
The power board is equipped with a variable resistor
(potenometer) to adjust high-voltage output. Output
has been pre-set for opmum eciency. As voltage
varies in extreme condions of dryness, humidity, or
proximity to hydro towers, raising or lowering
potenometer allows for proper voltage output.
Air-Proving Switch (APS): Integrated. Automacally
cycles air cleaner ON and OFF with the system fan.
The APS will detect airow (fan on) and energize the
air cleaner.
Collecng Cells: Consist of an ionizing secon and a
collector plate secon. The arrow on the cell must point
toward the system fan (in the direcon of the airow).
Prelters: Constructed of aluminum mesh to prevent lint
and large parcles from entering the collecng cells.
Carbon VOC Filters: Remove odors. Maximum of (3)
carbon VOC lters can be used at the same me.
120V MODELS AE14-1620-51 AE14-1625-51 AE14-2020-51 AE14-2025-51
240V MODELS AE14-1620-52 AE14-1625-52 AE14-2020-52 AE14-2025-52
House Size Area
(typical)
up to 2400 ²
up to 223 m²
up to 3000 ²
up to 279 m²
up to 3000 ²
up to 279 m²
up to 4000 ²
up to 372 m²
Airow
up to 1200 CFM
up to 2040 m³/hr
up to 1400 CFM
up to 2380 m³/hr
up to 1400 CFM
up to 2380 m³/hr
up to 2000 CFM
up to 3400 m³/hr
Duct Size
16 x 20 in
40.5 x 51.0 cm
16 x 25 in
40.5 x 63.5 cm
20 x 20 in
51.0 x 51.0 cm
20 x 25 in
51.0 x 63.5 cm
Unit Weight
35 lbs
15.9 kg
37 lbs
16.8 kg
37 lbs
16.8 kg
41 lbs
18.6 kg
Input Voltage
AE14-XXXX-51 models
AE14-XXXX-52 models
120 V 60 Hz
220 V 50 Hz
120 V 60 Hz
220 V 50 Hz
120 V 60 Hz
220 V 50 Hz
120 V 60 Hz
220 V 50 Hz
Power Consumpon
(when operang)
30 Was
30 Was
30 Was 30 Was
Opons Available • Power Cord • Power Cord • Power Cord • Power Cord
Cercaons: C22.2 NO. 187-09 (R2014) – CSA Standard for Electrostac Air Cleaners UL 867 UL Standard for Electronic Air Cleaners.
This device is cered for shock and electrical hazard only
Figure 2
Collecting cells (2)
Prefilters (2)
Cabinet
Power box
Performance
indicator light
Power switch
Door
Activated carbon VOC
filters (3)
Figure 2: Air Cleaner Components