MAINTENANCE
IO-AE14-5
Reinstalling the Cells and Prelters
1. Once dry, inspect the cells for broken ionizer wires
and bent collector plates. Repair as necessary or
contact an authorized Clean Comfort service
technician to repair.
2. Re-insert the prelters into the upstream
prelter guides.
3. Re-insert the collector cells into the guides in the
boom center of the air cleaner cabinet; the airow
arrow points downstream (towards the furnace or
air handler) and the handle faces outward.
4. Firmly close the access door and turn power switch
ON. If the performance light does not come on or
arcing occurs, turn air cleaner OFF and allow air from
system fan to dry cells completely.
Replacing the Carbon VOC Filters
1. The acvated carbon VOC lters help remove odors
and light gases from the air exing the air cleaner.
They should be replaced every six months, or more
frequently with heavy use and should be done as part
of the scheduled cleaning when the cells and prelters
are cleaned. Carbon VOC Filters are NOT washable.
2. Replacement carbon VOC lters are available in the
same size and conguraon as the original unit. They
can be purchased from your Clean Comfort authorized
service technician.
1. Turn air cleaner power switch OFF
2. Turn OFF system fan
3. Open access door
4. Remove collecng cells from air cleaner
5. Remove the used carbon VOC lters from air cleaner
6. Put new carbon VOC lters into air cleaner. Space lters
evenly across the discharge opening of air cleaner.
Never put more than 3 carbon VOC lters in the air
cleaner, as this may cause a problem with airow.
Figure 7: DAX Detergent and Carbon VOC Filters are available
from your installer or dealer.
Maintenance Parts
Item Part #
DAX 32 oz Spray Bole AEP-FS9900
Replacement Carbon VOC Filters:
AE14-1620-51,-52 (Set of 3) AEP-1156-3
AE14-1625-51,-52 (Set of 3) AEP-1156-3
AE14-2020-51,-52 (Set of 3) AEP-1856-3
AE14-2025-51,-52 (Set of 3) AEP-1856-3
Cleaning Record
The collecng cells and prelters must be cleaned on a
regular basis for the air cleaner to funcon at its peak
eciency. The frequency of cleaning will vary from
one house to another. On average, the cells should be
cleaned every 3 months. Use the chart below to keep
track of your cleaning schedule.
Cleaning Record
Date Cleaned Performed by