User`s manual
5.2 Charge Current Setting
• Recommended battery capacity versus charging currents (at 20°C battery temperature)
Charge
Current
Recommended Battery
Capacity Range
15 A 75 – 150 Ah
20 A 100 – 200 Ah
25 A 100 – 250 Ah
30 A 150 – 300 Ah
40 A 200 – 400 Ah
50 A 250 – 500 Ah
60 A 300 – 600 Ah
80 A 400 – 800 Ah
120 A 600 – 1200 Ah
ATTENTION!
• If sealed lead acid batteries are overcharged it will result in gassing and dry-out and the battery will
be destroyed.
• Wet batteries (open type) will loose water and need to be topping up.
• If you are in doubt how your battery / batteries shall be charged please consult your Battery
Technical Manual (data sheet), or your local battery distributor.
Temperature compensation (NTC sensor)
• When using the external temperature sensor (NTC) the charger will reduce the charge current with respect
the max allowed battery voltage at the actual temperature!
• Refer to scheme: at 20°C the boost charge max voltage is 14,4V
and float charge voltage 13,5V