User`s manual

Charger section:
Charge current adjust
The charge current can be adjusted by the potentiometer on the front panel top from 0A
up to maximum
rated charge current.
• See recommended charge current table in section 5.2 Charge Current Setting for correct adjustment.
Charge characteristic setup
• Future option!
Activate the charger
• The charger section will automatically switch on regardless of the ON/OFF power switch status, when 185-
265VAC is connected to the AC input (blue Neutrik)
Note: If the inverter is switched OFF
, the charger will operate at even lower voltage than 185VAC,
down to
110VAC is in this mode is accepted But with reduced charge current!
Note: If AC was connected and then removed (short charge time), the inverter can be restarted even if the
battery is still empty!
Charge power reduction
2300W (10A) from the AC grid should not be exceeded! The charger reduces automatically the charge
current if the total power exceeds 2300W (charge power + load power)
Note: the regulation is slow in order to allow load peak currents, without disturbing the charging!
Important: The device has a build in fuse – see FUSING section -, do not exceed this limit!
Boost charging
• Fast flashing green LED
, the charger delivers full charge current to the battery
Top charging
Slow flashing green LED
, the charge current is reduced in order not to exceed max battery voltage
allowed.
Fully charged battery
• Continuously light green LED
Deactivate the charger
• Remove AC, charging will stop.
Note: If the inverter was activated (ON) there will be 230VAC at the grey output connector (discharging)