1.1 Inverter mode:
1.1.1 Switch ON and OFF the inverter
Switch ON the inverter
Push down ON/OFF power switch for about 2 seconds. Both blue and red LED will light.
After 2 seconds red LED stops and the power switch can be released.
The blue LED will flash to indicate start up sequence
Blue LED lights and 230VAC is present.
Note: If the battery is discharged, then the red LED will continue to light; - recharge battery and
try again!
Note: The fan is running at full speed, while the power supply is starting up for acoustic
detection of the fan!
Switch OFF the inverter
Push down the ON/OFF power switch < 0.5 second
The blue LED stops lightning and the device shuts down
Remote ON/OFF
Use an external switch, to switch battery Plus to remote input terminal of Combi ON or
OFF.
1.1.2 Load search mode
In cases where it is preferable to leave the combi switched on and the load is periodically
inactive (switched OFF), the load search mode can be activated.
In this mode the Combi is partly active and generate a short pulse every 2 second, if a load
(>10W resistive) is detected, the device switches ON automatically. When a load is
disconnected again the device automatically returns to search mode (low consumption) after 1
min without load. - In load search mode the battery consumption is reduced to less than 2W in
order to save the battery during no load periods!
Activate load search mode
Switch OFF if the combi is activated; Push down the power switch for > 5 seconds; Release
only when the blue, green and red LED starts to light at the same time.
Note: in load search mode the battery consumption is reduced, while no load is active! The
device switch on automatically when a load is connected (> 10W resistive)
The load search mode will remain active, until deactivation or disconnection of the
battery longer than 15 minutes.
Note: there will be a small delay when connecting a load and until the device starts up
automatically!
Note: If load search mode is entered with a load connected, the blue LED flashes slowly only
for 5 seconds (to indicate entering of load search mode), then it lights continually!
Deactivate load search mode
Push power switch > 5 seconds; Release only when Blue, green and red LED start to flash at
the same time.
Note: The load search function will remain active if the device is switched ON/OFF by remote.
Note: Load search mode will also be deactivated, if battery is disconnected longer than 15
minutes.