User manual

G3-Combi
Clayton Power GmbH
Page - 15 -
3.2.3 Fusing
AC input
The Combi unit is equipped with a fuse at AC input side. In case of overload or charger error,
this fuse will blow.
Note: Only replace fuse with same type. (see electrical specification charger) Damage caused
by wrong fuse replacement is not covered by the guarantee.
AC output
The inverter section is fully protected against short circuit and overload, no fuse is required at
AC output side.
DC input
In addition it is recommended the fusing of the battery to prevent fire in the case of wrong
wiring, cable damage, short circuit, etc.
The fuse must be located to battery as close as possible,
and the screw joints must be firmly tight to prevent loose
connection, resulting in joint overheating and reducing
the efficiency of the fuse.
The current rating related to each model is displayed in
the table beside:
Note: The battery fuse does NOT prevent damage in
case of reversed battery polarity; such damage is
not covered by the guarantee!
Model
Battery fuse
rating
1012-50 125A slow-blow
1024-30 80A slow-blow
1312-80 175A slow-blow
1512-80 175A slow-blow
1524-40 100A slow-blow
2012-100 250A slow-blow
2324-50 150A slow-blow