User manual

G3-Combi
Clayton Power GmbH
Page - 11 -
2. SPECIFICATIONS
2.1 Electrical inverter specification
Model 1012 1312 1512 2012 1024 1524 2324 2336
POWER OUTPUT
Continuous output power FTS
(Full Temperature Scale)
1000W 1300W 1500W 2000W 1000W 1500W 2300W 2300W
Output power surge ( 1 sec. )
2000W 3000W 3000W 4000W 2000W 3000W 3000W 4000W
Output power surge ( 10 sec.) 1500W 1800W 2000W 2800W 1500W 1800W 3000W 3000W
Output power surge ( 15 min.) 1200W 1500W 1700W 2200W 1200W 1700W 2500W 2500W
Max. efficiency 90%
CONSUMPTION
No load power consumption 10W 15W 10W 15W 17W
Load search mode
consumption
< 2W
Sleep mode consumption < 5mA
THERMAL MANAGEMENT
Max operating temperature +50°C
Min operating temperature -20°C
Max internaltemperature
(inverter shut down)
+80°C
VOLTAGE OUT
Nominal output voltage 230VAC
Output Voltage tolerance -10% to +5%
Output Voltage tolerance(at
input voltage 25V to 31.5V)
-18% bis
+5%
Frequency 50Hz
Output wave form Sinus
THD max. 3%
VOLTAGE IN
Battery input voltage
(nominal)
12VDC 24VDC 36VDC
Max input voltage
15VDC
30VDC 45VDC
Low battery voltage cut-off
(Slow reaction 3 Sec.)
10,5VDC 21VDC 25VDC
Low battery voltage cut-off
(Fast reaction<10mS)
9VDC 18VDC 23VDC
Voltage beforeinverter can
switch ON again(after a low
battery cut-off)
12,75VDC 25,5VDC 38,25VDC