User manual

15
Data connections
The connectors in position 9 and 10 are a RJ12 of type 6P6 connector.
Pin #
Signal
Description
1
-TempX
Negative connection for NTC temperature sensor
2
User GND
User ground (fused)
3
+TempX
Positive connection for NTC temperature sensor
4
Not Used
Do not connect
5
DATA
Clayon Power Single Wire communication
6
Remote
If connected to positive battery voltage, it will switch on the G3 Combi
If left open, it will have no influence
The connector in position 11 is a Phoenix Combicon MSTB 2.5 / 3-ST-5.08
Pin #
Signal
Description
1
DATA
Clayon Power Single Wire communication
2
Remote
If connected to positive battery voltage, it will switch on the G3 Combi
If left open, it will have no influence
3
Not Used
Do not connect
The two signals DATA and Remote are internally connected.
Pin 1
RJ12
Pin1
Phoenex