User manual

11
Charger mode
Activate the charger by applying 230 Vac to the AC input.
Minimum voltage
Maximum voltage
Normal voltage range
185 Vac
265 Vac
Extended voltage range*
110 Vac
265 Vac
* The extended range is available if the inverter mode is not active. In the extended range the
device will charge with reduced current (10A).
The charge is a fully automatic 3-stage charger with IUoUo characteristic.
Charge current adjustment
It is possible to reduce the charge current by adjusting the charge current potentiometer (2).
Note: the scale is in amperes out of the DC terminals, thus if adjusting e.g. a 1012-50 unit, the
adjustment will have no effect from 50 100.
Automatic charge current reduction
The device output is rated for 2300 W when AC is present on the input for all the Combi
devices. If the load power + maximum charging power exceed 2300 W, the charger will reduce
the charge current to maintain a maximum of 2300 W from the input.