User manual

10
The device can also be activated by placing a voltage on the remote pin of one of the three
connectors on the front of the device. This is illustrated in the schematic below.
If the device is connected to a Clayton Power Lithium battery with data the inverter will by
default start when the battery is activated. To change this behavior, please refer to the Clayton
Power Lithium Battery User Manual.
Note: if the battery is discharged the red LED will continue to light. Recharge the battery and try
again.
Inverter Load Search Mode
The inverter can be put into load search mode to lower the standby power consumption.
When the inverter is in load search mode, the inverter will automatically shut down when the
AC load is lower than 10 W. The inverter will turn on every 2 seconds and detect if a load is
present.
Press duration
Precondition
Function
2 seconds
Inverter mode is Off
Turn on inverter mode
1 second
Inverter mode is On
Turn off inverter mode
10 seconds
Inverter mode is Off and
not in load search mode
Unit enters load search mode
All LEDs lights solid
10 seconds
Inverter mode is Off and
not in load search mode
Unit exits load search mode
All LEDs blink
Note: When using the device with a Clayton Power Lithium battery it is not advised to use
load search mode.