Manual

TEST MENU
S E
ENTERSELECT
PO
Press SELECT twice.
The red led lights up and
the display shows: OPt.
S E
ENTERSELECT
CF
Press ENTER to access
FC function.
S E
ENTERSELECT
S
Press UP/DOWN to
select tSt menu.
Press ENTER to confirm.
The display shows: FC.
S E
ENTERSELECT
S E
Press UP/DOWN to
select SE function.
Press ENTER to confirm.
S E
ENTERSELECT
Three segments light up
on the display and an
automatic movement
sequence starts for
testing.
S E
ENTERSELECT
S
Colour
Pan
(Horizontal movement)
Tilt
(Vertical movement)
The letter S appears on the left-hand display and turns on
three segments on the right-hand display, depending on
the current status of the reset sensors.
S E
ENTERSELECT
CF
Press SELECT to exit
the function.
The display shows:
FC.
S E
ENTERSELECT
ES
Press SELECT to exit
the function.
MENU
P ln.
t
ln.
H
lr.
F
C.
S
C.
d
On.
d
OF.
F
AC.
u
C
Pan inversion
Tilt inversion
Pan/Tilt high resolution
Positioning on only full colours
Lamp off during colour change
Display at maximum luminosity
Display off
Resets settings
O t .p
FC .
S
E.
Limit switch sensors test
Automatic test movements
t t .s
A t .u
E nA.
C
OL.
S
EL.
r
l.
L
.
t
l
H
EA.
P
An.
A
A
Operating
mode
Colour disc
operating mode
Colours
selection
Rainbow
Speed
Lamp
operation
Colour disc
step time
Pan/Tilt
movement
Min and max
Pan position
t
lL.
Min and max
Tilt position
S
Pd.
Pan/Tilt
speed
F
AC.
Resets
settings
.
S A.
S
LA.
S
At .
Mode SLAVE (works with DMX signal)
Mode STAND-ALONE (automatic operation)
Mode MASTER (generates DMX signal)
r
A.
S
E
A
u
It is positioned on colours selected with SEL
Colour disc rotation
Selects random colours
.
.
C
1
C
7
.
.
÷
O
n
O
F
.
F.
6 0.
3
0
1
2
.
0.
S
LO.
O
n
F
s
Lamp always on
Gradual on and off
Rapid on and off
.
T.
3. 6. 2.1 4.2
0.6 0. 0.42 0.6321
S
nd.
A
u Automatic movement
Movement with sound signal
.
H
l
L
o.
.
0.
0.
5.52
5.52
÷
÷
O n
O
F
.
F.
H l
L
o.
.
0.
0.
5.52
5.52
÷
÷
S P1.
S
P2.
S
P3.
S
P4.
S
P5.
OPTIONS
MENU
AUTO
MENU
TEST
MENU
MENU STRUCTURE
FC
FUNCTION
: status of the limit switch sensors
SE
FUNCTION
: test movements
CLAY PAKY SPA - Via Pastrengo, 3/b - 24068 Seriate (BG) - Italy - Tel. +39-035-654311(10 linee) - Fax +39-035-301876 - Internet: www.claypaky.it
studio
Rev. 0 07/03 Cod. 099485GB
Press SELECT twice to return to rest mode.
Press SELECT twice to return to rest mode.
S E
ENTERSELECT
OFd
Press UP-DOWN to
select dOF function.
Press ENTER to access
the function.
S E
ENTERSELECT
nO
S E
ENTERSELECT
1
Using the UP/DOWN but-
ton, select On to activate,
Off to disconnect.
Press ENTER to confirm.
The display shows:
dOf.
This function turns off the display after 80 seconds if it has
not been used. Press any button to turn it back on.
dOF
FUNCTION
: display off
VIEWING THE DISPLAY THE OTHER
WAY ROUND
Press UP/DOWN at the
same time, out of the
menus (red led off), to
view the display the other
way round or viceversa.
Press SELECT twice to return to rest mode.
SE
ENTERSELECT
C
FA
Press UP-DOWN to
select settings reset
FAC function.
S E
ENTERSELECT
?
Press ENTER to access
the function.
Press ENTER to reset
settings, or:
SETTING RESETS
You can reset programmed settings in both the Aut
automatic menu and Opt options menu.
Resetting settings in Aut automatic menu
S E
ENTERSELECT
OP
S E
ENTERSELECT
Au
Press SELECT twice.
The red led lights up and
the display shows: OPt.
Press UP/DOWN to
select the automatic Aut
menu.
Press ENTER to confirm.
The display shows: EnA.
Press SELECT twice to return to rest mode.
SE
ENTERSELECT
C
FA
Press UP-DOWN to
select Settings Reset
FAC function.
S E
ENTERSELECT
?
Press ENTER to access
the function.
Press ENTER to reset
settings, or:
Resetting settings in Opt options menu
S E
ENTERSELECT
OP
Press SELECT twice.
The red led lights up and
the display shows: OPt.
Press ENTER to confirm.
The display shows: Pln.