Installation and Setup Guide Clavister SG3200 Series Clavister AB Torggatan 10 SE-891 28 Örnsköldsvik SWEDEN Phone: +46-660-299200 Fax: +46-660-12250 www.clavister.
Installation and Setup Guide Clavister SG3200 Series Published 2008-01-21 Build: 890 Copyright © 2008 Clavister AB Copyright Notice This publication, including all photographs, illustrations and software, is protected under international copyright laws, with all rights reserved. Neither this manual, nor any of the material contained herein, may be reproduced without written consent of the author. Disclaimer The information in this document is subject to change without notice.
Table of Contents Preface ................................................................................................................ 5 1. Product Overview .............................................................................................. 6 1.1. Unpacking the Product ............................................................................. 6 1.2. Ports and Connectors ............................................................................... 7 2. Installation .......................
List of Figures 1.1. Front view of the Clavister SG3200 Series. .......................................................... 7 2.1. SG3200 Rear View .........................................................................................11 3.1. A Typical SG3200 Series Installation Setup ........................................................13 3.2. SG3200 Local Console Connection ....................................................................14 6.1. SG3200 Series Dimensions and Weight .................
Preface Target Audience The target audience for this guide is the user who has taken delivery of a packaged Clavister SG3200 Series appliance. The guide takes the user from unpacking and installation of the device through to power-up and initial network connection. Text Structure The text is divided into chapters and subsections. Numbered subsections are shown in the table of contents at the beginning of the document.
Chapter 1. Product Overview • Unpacking the Product, page 6 • Ports and Connectors, page 7 1.1. Unpacking the Product This section details the unpacking of the SG3200 Series appliance. Open the packaging box used for shipping and carefully unpack the contents. The box should contain the following: 1. The Clavister SG3200 Series Appliance. 2. A mounting kit for 19" racks . The side brackets for this kit are already be attached but can be removed for flat surface operation. 3.
1.2. Ports and Connectors Chapter 1. Product Overview 1.2. Ports and Connectors This section is an overview of the hardware's external design and construction. Figure 1.1. Front view of the Clavister SG3200 Series. The SG3200 features a number of connection ports: • On the far left is a RS232 port for direct console access. • To the right of the console port are 2 USB ports which are not used in normal CorePlus operation.
Port Status LEDs Chapter 1.
Chapter 2. Installation • Installation Guidelines, page 9 • Connecting Power, page 11 2.1. Installation Guidelines Follow these guidelines when installing your Clavister SG3200 Series appliance: • Make sure that the power source circuits are properly grounded, then use the power cord supplied with the appliance to connect it to the power source.
Rack Installation Chapter 2. Installation • A rack or cabinet used for mounting should be adequately secured to prevent it from becoming unstable and/or falling over. • Devices installed in a rack or cabinet should be mounted as low as possible, with the heaviest devices at the bottom and progressively lighter devices installed above.
2.2. Connecting Power Chapter 2. Installation 2.2. Connecting Power This section describes connecting power to the SG3200. Power should not actually be switched on using the On/Off switch until after the local console has been connected as described in Section 3.1.2, “Connecting the Console Port”. The reason for this is that as soon as power is applied the boot-up dialog sequence will appear on the console screen. Figure 2.1.
Connecting AC Power Chapter 2.
Chapter 3. Initial Setup • Attaching Connectors, page 13 • Local RS232 Console Setup, page 15 • Finalizing the Configuration, page 17 3.1. Attaching Connectors 3.1.1. Connecting to a Network The initial configuration of the SG3200 Series device configures which Ethernet interface is to be used for remote management. Any interface can be used for this purpose. The selected interface can also be used for normal traffic.
3.1.2. Connecting the Console Port Chapter 3. Initial Setup null-modem cable. To connect a terminal to the console port, follow these steps: 1. Set the terminal protocol as described previously. 2. Connect one of the connectors on the RS-232 cable supplied, directly to the console port on the SG3200 Series device. 3. Connect the other end of the cable to the terminal or the serial connector of the computer running the communications software. Figure 3.2.
3.2. Local RS232 Console Setup Chapter 3. Initial Setup 3.2. Local RS232 Console Setup Make sure that a terminal (or a computer running terminal emulation software such as Hyper-Terminal) is connected to the console port on the Clavister SG3200 Series hardware as described above in Section 3.1.2, “Connecting the Console Port”. 1. Having previously followed the instructions in Section 2.2, “Connecting Power”, the device should now be powered up.
3.2. Local RS232 Console Setup Chapter 3. Initial Setup Tip When entering IP addresses, use the "." (period) key to move the console cursor from one part of the IP address input field to the next. The Default Gateway does not need to be specified if the management workstation is local.
3.3. Finalizing the Configuration Chapter 3. Initial Setup 3.3. Finalizing the Configuration After intial setup, the user should refer to the companion publications found in PDF format on the accompanying CD for information on how to begin to configure the SG3200 Series device: Clavister CorePlus Administrators Guide This describes the general operation and control of the CorePlus firmware, which is the Clavister proprietary operating system that drives and controls the Clavister SG3200 Series hardware.
3.3. Finalizing the Configuration Chapter 3.
Chapter 4. Warranty Limited Warranty Clavister warrants to the customer of the SG3200 Series Appliance that the Hardware components will be free from defects in material and workmanship under normal use for a period of two (2) years from the Start Date (as defined below). The warranty will only apply to failure of the product if Clavister is informed of the failure not later than two (2) years from the "Start Date" or thirty (30) days after that the failure was or ought to have been noticed by the customer.
Limitations of Liability Chapter 4. Warranty Customer Remedies Clavister's entire liability according to this warranty shall be, at Clavister's option, either return of the price paid, or repair or replacement of the Hardware that does not meet Clavister's limited warranty and which is returned to Clavister with a copy of your receipt. Limitations of Liability Refer to the legal statement at the beginning of the guide for a statement of liability limitations.
Chapter 5. Safety Safety Information Clavister SG3200 Series devices are safety class I products and have protective ground terminals. There must be an uninterrupted safety earth ground from the main power source to the product’s input wiring terminals, power cord, or supplied power cord set. Whenever it is likely that the protection has been impaired, disconnect the power cord until the ground has been restored.
Hinweise zur Sicherheit Chapter 5. Safety Aucune pièce contenue à l’intérieur de ce produit ne peut être réparée par l’utilisateur. Tout dépannage, réglage, entretien ou réparation devra être confié exclusivement à un personnel qualifié. Hinweise zur Sicherheit Dies ist ein Gerät der Sicherheitsklasse I und verfügt über einen schützenden Erdungsterminal.
Consideraciones sobre seguridad Chapter 5. Safety • Si la LAN abarca un área cuyo suministro eléctrico proviene de más de una red de distribución de electricidad, cerciorarse de que las puestas a tierra estén conectadas entre sí de modo seguro. • Es posible que los cables de la LAN se vean sometidos de vez en cuando a voltajes momentáneos que entrañen peligro (rayos o alteraciones en la red de energía eléctrica). Manejar con precaución los componentes de metal de la LAN que estén al descubierto.
Chapter 6. Hardware Specifications Below are the key hardware specifications for Clavister SG3200 Series installation. Figure 6.1. SG3200 Series Dimensions and Weight Height x Width x Depth (mm) 44 x 431 x 361 Device weight 4.4 kg Device form Factor 1U Rack Mountable 19" ? Yes Power Supply (AC) 100-240V 50 to 60 Hz AC Power Supply (DC) 36VDC to 72VDC Figure 6.2. Regulatory and Safety Standards Safety UL, CE EMC FCC class A, CE class A, VCCI class A Figure 6.3.