System Functions
ABOUT SYSTEM SETTINGS
System settings are global; they are not stored within a
program, but applies to all programs all of the time.
The system settings are divided into 3 menus:
• System menu
•MIDI menu
• Sound menu
A list of each menu and it’s functions is printed on the front
panel.
CHANGING SYSTEM SETTINGS
To change a a system function:
1
Select the appropriate menu
Press SHIFT + SYSTEM / MIDI / SOUND buttons.
2
Select function
The current functions number is shown in the DIS-
PLAY, as well as it’s current setting. Navigate through
the available functions by using the
PROG/MENU but-
tons.
3
Change setting
Press SHIFT + VALUE buttons to navigate though the
functions possible settings.
Changes are automatically saved.
4
Press any of the SYSTEM / MIDI / SOUND buttons to
exit the menu
THE SYSTEM MENU
THE MIDI MENU
1 Memory protect default value: OF
ON Program store is disabled.
OF Program store is enabled.
2 Output Routing default value: ST
SP Split Output: tonewheel organ is directed to HIGH LEVEL
OUT and LEFT OUT.
Electric-V and Electric-F organs are directed to RIGHT
OUT.
ST Stereo Output.
3 Transpose default value: 0
-6 - +6 Sets transpose of both manuals and BASS PEDAL input in
range of -6 semi notes to + 6 semi notes, steps of 1 semi
note.
4 Fine Tune default value: 40
27 - 53 Sets the tuning from 427 Hz to 453Hz, in steps of 1 Hz.
Default value is 40 (440Hz).
5 Sustain Pedal Polarity default value: CL
CL Pedal Closed: for use with a sustain pedal with closed polar-
ity.
OP Pedal Open: for use with a sustain pedal with open polarity.
6 Sustain Pedal default value: ON
Controls weather the selected organ model should respond to sustain
pedal messages. When a pedal is connected to the SUSTAIN PEDAL
input, sustain pedal messages are always send via MIDI OUT regard-
less of this setting.
ON Sustain pedal messages enabled.
OFF Sustain pedal messages disabled.
7 Rotary Control Type default value: CL
Specifies the type of controller connected to the Rotary Control input.
If the Half Moon Switch option is selected the speed control buttons
on the front panel are disabled.
HA Half Moon Switch: for use with the Half Moon Switch acces-
sory.
OP Pedal Open: For use with a sustain pedal with open polarity.
CL Pedal Closed: For use with a sustain pedal with closed
polarity.
8 Rotary Pedal Mode default value: HD
TO Toggle: rotary speed is changed between SLOW and FAST
each time the pedal is pressed down. By holding the pedal
pressed downed for the duration of 1 second the speed will
change to STOP.
HD Hold: rotary speed follows the state of the pedal.
9 Swell Pedal Type default value: RO
Here you can match the swell pedal characteristic for various manu-
facturers.
FA Fatar.
ER Ernie Ball.
YA Yamaha.
RO Roland.
10 Factory Reset
Press STORE to recall all system settings. Stored PROGRAM MODE
data is not affected. LIVE 1 and LIVE 2 data will be overwritten.
1 Upper Channel default value: 1
Sets how messages are sent and received from the UPPER manual via
MIDI IN and MIDI OUT.
OFF Messages are not sent.