Operating instructions
9
Locate in the control sack kit (2) cables.
Longest one is for the Temperature lever .
Attach this with (1) #8 x 5/8” pan head philip
screw and the cable clamp provided.
Short cable is attached to the mode control
lever. Hold cable over edge of the control head
as shown below. Mark and drill a 1/8” Dia.
hole and attach the cable with (1) #10 x 5/8”
pan head philips screw.
Set aside for later installation.
Locate the Inlet Block off Plate.
Located above the glove box opening place
block off plate over the hole. Attach with (2)
#10 x ¾ “ hex washer head tek screws.
Place ¼-20 J-clip over mounting flange as
shown.
Drill 1/8” Dia hole.
CABLE CLAMP
¼-20 J-clip