Operating instructions

21
Locate the Suction Hose. The hose has (2) 90 Deg. fittings pre-attached in the correct
position. One of the ends has a service port, this should be attached to the compressor.
The other end will attach to the suction tube coming from the evaporator assembly. Use
#10 o-rings and apply oil before attachment.
Tighten all fittings.
Locate female bullet connector that is supplied
with the Hi-Low pressure switch.
Cut one of the white wires from the pressure
switch. Attach the bullet connector to this wire
and plug into the compressor clutch wire.
Route the long white wire from the pressure
switch along the suction hose and connect to
clutch wire that was inserted through the
firewall.
Use ty-raps supplied and attach hoses to the
tower supports.
Congratulations you have completed the install of your
CLASSIC AUTO AIR “Perfect Fit Series” system.
Liquid hose
Suction hose
Carefully route liquid and suction hoses