Installation manual
21
We’ve included enough wire length to allow you to mount the ECU in a variety
of places. It is very important that you mount this in a place where it will stay dry
and that vibration is at a minimum. Also make sure that where ever you mount it
does not interfere with any moving controls or cables. We recommend
mounting it just above the right hand side of the main unit using the included
tek-screws. IMPORTANT! DON’T MOUNT THE ECU PERMANENTLY JUST
YET. THAT CAN BE DONE AFTER YOU CALIBRATE THE UNIT (SEE NEXT
PAGE).
In Bag Kit D you will find three wiring harnesses with connections at each end.
Plug the harness with YELLOW band into the YELLOW ECU port and the other
end into the servo motor on the main unit (motor is marked with YELLOW
INDICATOR). Repeat this process for the other two harnesses, following the
color coding indicated on cables and ports. Attach cable in the engine
compartment to the electronic water valve (see figure 27). Using one of the CAP
PLUGS provided, slot it and install over the heater hose/cable.
NOTE: The GREEN harness connection will be made from the harness you
previously installed, just plug the loose connection in the CONTROL
port on the ECU.
FACE/FLOOR
POWER
CONTROL
WATER VALVE
DEFROST
INSTALL (2) CAP PLUGS
OVER HOLES.
SLOT ONE FOR THE CABLE.
FIGURE 27
FIREWALL
www.classicautoair.com • 866.435.7801