Owner`s manual

16
NOTE: e Balanced (XLR) Output pin assignments adhere to
the AES (Audio Engineering Society) “Pin 2 = hot” standard. e
XLR male outputs carry the following pin assignments:
Pin 1: Signal ground
Pin 2: Signal + (non-inverting)
Pin 3: Signal – (inverting)
Connector ground lug: chassis ground
Refer to the operating manuals of your balanced-input power
ampliers to verify that the pin assignments of their input
connectors adhere to this standard (Classé power ampliers are
compliant). If your ampliers are not compliant, it may not pose a
problem, but ask your Classé dealer for assistance.
13 Ethernet Connector
is connector is provided for an optional hardware module that will be
made available in the future. It is inoperable until the optional module has
been installed.
14 Main Power On/Off Switch
is switch connects and disconnects the CP-800 from AC.
15 AC Power Cord Input
e detachable three-conductor AC power cord and the socket into
which it connects conform to rigorous standards developed by the IEC
(International Electrotechnical Commission).
Danger! Your CP-800 contains potentially dangerous voltages and
current capabilities. Do not attempt to open it! There are no
user-serviceable parts inside. All service must be referred to a
qualified authorized Classé dealer or distributor.