Owner`s manual

30
hardware setup 1 Classé Delta Series Products
Two or more Classé Delta series products are required, at least one of which
must have a touchscreen display.
2 Category 5 Network Cables
ese are ordinary network cables, commonly used for broadband Internet
connections.  ey should be typical “straight through” cables not the “crossed
over” type, and the total required will be one less than the total number of
Delta series components in your system.
3 CAN-Bus Terminator
A single CAN-Bus Terminator may be required. It is inserted into the
CAN-Bus OUT connector of the last component in the CAN-Bus
daisy chain. One is
included in the box with your CDP-300. T
hey are also
available free of charge from your nearest Classé Customer Support Centre
http://www.Classeaudio.com/support/service.htm
4 SSP-300 & 600 CAN-Bus Interface Box
Systems that include an SSP-600 or SSP-300 will also require an
SSP-300/600 CAN-Bus Interface Box.  ese are included with the products or
available free of charge
from your nearest Classé Customer Support Centre
http://www.Classeaudio.com/support/service.htm
e following diagrams illustrate how to connect the CAN-Bus hardware.
Any combination of models in any order without SSP-300 or SSP-600.
OUT
CAN-BUS
IN
OUT
CAN-BUS
IN
OUT
CAN-BUS
IN
OUT
CAN-BUS
IN
Downloaded From Disc-Player.com Classe Audio Manuals