o Electric motors and wiring are protected by a circuit breaker. DO NOT remove or
bypass the circuit breaker, as severe damage to the electric motor or apparatus
wiring could occur.
Be careful that NO part of your body (head, feet, arms, legs, fingers, hair, etc.) is in an area
of rotating or moving parts.
Certain internal parts of the Class 1 valve assembly may be under tension. When servicing
the valve, wear eye protection and exercise care when removing these parts.
Fasteners used for the assembly of the Class 1 valves are plated Grade 8 steel.
Foreign materials, like metal chips or shavings, can destroy the plastic seals on the valves.
Machine connected parts and remove foreign materials prior to installing the Class 1 valve.
If your Class 1 valve includes the Slow-Close option, do not tamper with the slow-close
actuator. There are no serviceable parts inside. The actuator must never be disassembled.
Contact Class 1 for a replacement assembly.
o Current NFPA 1901 Standards specify that a minimum of three seconds is required
to open or close a 3” or larger valve.
DO NOT exceed the rated Class 1 valve operating pressure, shown below:
MODEL
RATED OPERATING PRESSURE
C20 (2.0”)
400 psi (1724 kPa)
C25 (2.5”)
400 psi (1724 kPa)
C30 (3.0”)
400 psi (1724 kPa)
4. Safety Information