Manual

FoamLogix, Model 2.1A and 1.7AHP Class “A”
Electronic Foam Proportioning Systems
67
When the 1 FLOW LED lights, press and release
the and buttons at the same time.
The display shows 2 S 150 (or other preset default
value) and the FLOW LED lights. (See Figure
41: “Display - Simulated Flow Operation” on
page 64.)
Press the 3 ON button. The left-most LED on
the bar graph lights and the foam pump begins
running.
Foam concentrate ows out of the end of the
bypass hose.
To End Simulated Flow
First press the 1. ON button to STOP the foam
pump.
Press the 2. i button until the FLOW LED
lights.
Press and release the 3. and buttons
at the same time. The display shows the
current water ow value and the FLOW LED
lights.
De-energize the apparatus electrical system. 4.
Place the bypass valve to the INJECT 5.
position.
Secure bypass hose in the appropriate 6.
compartment.
Return apparatus to normal ready condition. 7.