Owner manual

3
User Menu
MENU TEST LTS SELECT All display segments & LED’s illuminate, alarm
sounds.
MENU UNITS: (E / M) SELECT toggles units of measurement
MENU ALERT?: (Y / N) SELECT allows/disables audible alarm signal
MENU HOURS SELECT cycles through PTO, User, Engine, and Incident
timers
MENU return to top.
SILENCE save and exit
USER MENU
Defaults:
Service time interval 100 hours
Aux. input AUX IN
Aux. Hours AUX HR
Logo CLASS1
Low Voltage Alarm YES
Temperature DEG:CLNT
Low Oil Pressure 10 PSI
High Temperature 230
o
F
Low Voltage Alarm 11.9 VDC
Overvoltage 15.0 VDC
To enter the User Menu, engine RPM can not be greater than 900.
Press the
MENU switch.
Scroll through menu items by pressing the MENU switch.
Select items from the menu by pressing the
SELECT switch.
After Selection, change items by pressing the SELECT switch.
Save information and exit from the menu by pressing the SILENCE switch.