Manual
7
MESSAGES
Alert Messages are preceded by a short
tone burst to alert the operator. The cause
for the alert is then displayed on the mes-
sage center, alternating with other infor-
mation.
Alert Messages:
PTO ENGD PTO engagement
CHK ENG Check Engine
LDMGR ON Load Management
TANK LOW Tank Level
LM-LVL:x (1-8) Shed level
Normal Messages appear without any audible warning.
AUX HRS ** User hours
CLASS 1 ** Logo
SRVC PTO Service reminder for PTO
Defaults Settings:
Service time Interval 100 hours
Aux. Input Display AUX IN
Aux. Hours Display AUX HR
Logo CLASS1
Low Voltage Alarm YES
Temperature source DEG:OIL
Low Oil Pressure 10 PSI (69 kPa)
High Temperature 230
o
F (110
o
C)
Low Voltage Alarm 11.9 VDC
Overvoltage 15.0 VDC
* Alarm Points are set by the OEM. ** OEM configurable messages
Alarm Messages are accompanied by a
pulsed alarm that continues until silenced
or the cause eliminated. The alarm mes-
sage is displayed in the message center
and LO or HI is displayed on the appropri-
ate display for temperature, oil and volt-
age alarms.
AUX IN ** User Input
LOW FUEL less than 1/4 tank
STOP ENG Stop Engine
CHK BATT * System Voltage low
CHK ALT * System Voltage high
LOW OIL * Oil Pressure low
HI TEMP * Temperature high
Oil and Temp. alarms are active only with
engine running.