User Manual
10
Negative Master Switch and Ground Output
PN 101084 ESM
TB #15 + Output Overvoltage Light or Fast Idle Control
TB #14 - Input System Ground
TB #13 + Input Ignition (Main battery monitor voltage)
TB #12 + Input Isolated Battery monitor voltage
TB #11 - Input Load Manage Enable (shed)
TB #10 - Input Master Switch
TB # 9 - Input System Override
TB # 8 - Output Battery Low Warning Light
TB # 7 - Output Load 7 or isolated battery low light
TB # 6 - Output Load 6
TB # 5 - Output Load 5
TB # 4 - Output Load 4
TB # 3 - Output Load 3
TB # 2 - Output Load 2
TB # 1 - Output Load 1
Positive Master Switch and Ground Output
PN 101119 ESM
NOTE:LOADS 1 & 2 DO NOT SHED, MAIN BATTERY MONITORING ONLY.
LOADS SEQUENCE ON 1-7, SEQUENCE OFF 7-1 AND SHED 7-3.
TB #15 + Output Overvoltage light or Fast idle control
TB #14 - Input System Ground
TB #13 + Input Ignition (Main battery monitor voltage)
TB #12 + Input Master Switch
TB #11 - Input Load Manage Enable (shed)
TB #10 No Connection
TB # 9 - Input System Override
TB # 8 + Output Battery Low Warning Light
TB # 7 - Output Load 7
TB # 6 - Output Load 6
TB # 5 - Output Load 5
TB # 4 - Output Load 4
TB # 3 - Output Load 3
TB # 2 - Output Load 2
TB # 1 - Output Load 1
Terminal Block I/O Polarity