User guide

page 4 of 4 pages
Engineering
Standards
Name
Identifier OEM Installation and Calibration
Engineering Standard Number
C1-102007-A
Digital Speedometer Information
5. Calibration
Digital Speedometer Calibration is performed with the vehicle speed stabilized at 40
MPH or 40 KPH.
The calibration mode is enabled by the use of a password.
Enter the switch sequence below to enter calibration mode.
L L L R R R
Left Switch Left Switch Left Switch Right Switch Right Switch Right switch
If the password is correctly entered,
Cal Cal
Cal Cal
Cal
will be displayed for 1/2 second followed
by
40 40
40 40
40
.
Establish a stable vehicle speed of 40. Maintain this speed for a minimum of 15
seconds.
Activate the left switch.
The display will read
donE donE
donE donE
donE
followed by the active speed.
Calibration is now complete.
6. Operation
The speedometer will display current vehicle speed whenever the display is enabled
and a valid speedometer signal is received.
Range is from 0 to 120 Miles per Hour (MPH) or Kilometers per Hour (KPH) depen-
dent on the units used for calibration.
SPEEDOMETER
C:\MANUALS\DIGITAL\SPEEDO\SPDO_ESN.P65_121597