User guide
page 4 of 6 pages
Engineering
Standards
Name
Identifier Instructions
Engineering Standard Number
C1-102190-A
Digital Pressure Gauge
PIN COLOR FUNCTION
A BLACK SENSOR GROUND
B RED SENSOR SUPPLY
C WHITE SENSOR SIGNAL
PIN COLOR FUNCTION
1 PLUG
2 WHITE SIGNAL
3 RED SENSOR SUPPLY
4 RED POWER IN
5 BLACK GROUND IN
6 BLACK SENSOR GROUND
7 PLUG
8 PLUG
Installation and Operation of the Class1 Digital Pressure Gauge.
The pressure transducer (PN 102161) mounts to the pump with a 1/4” NPT fitting. Mount
the pressure transducer on the pump discharge manifold and tighten using the 1-1/4 hex.
Mount the digital display on the pump panel using the dimensions provided.
Connect the wiring harness PN 102035, 102060, or 102061 to the transducer, the display
and to the vehicle power and ground circuits.
Operation is straightforward.
When the unit is turned on, the display indicates pump pressure at the trans-
ducer location. Normally no calibration is required, however if the gauge
does not read zero when the pump is not running, a ZERO calibration can be
performed. Password L R R L L.
This feature is available only on rP1.7 and above.
Harness PN 102060 5’
102035 10’
102061 20’
Red +12 VDC
Black Ground
Pressure Gauge
PUMP DISCHARGE
1
2
3
4
8
7
6
5
Wire Insertion View