PIN COLOR CIRCUIT
1 OEM Alarm
2 BLACK Signal
3 RED 10 VDC
4 RED V IGN
5 BLACK GND
6 Black Sensor -
7 PLUG ---
8 OEM Silence
PRIMARY DISPLAY
PIN COLOR CIRCUIT
1 RED 10 VDC
2 BLACK SIGNAL
DISPLAY 2 Signal Wire
SENSOR
PIN COLOR CIRCUIT
1 BLACK SIGNAL 1
2 WHITE SIGNAL 2
3 BLACK XDucer IN
4 RED V IGN
5 BLACK GND
6 PLUG --
7 RED T V+
8 PLUG --
DUAL OUTPUT CONVERTER
12"
12"
2.5'
5'
2.5'
2.5'
10'
Ignition
Ground
PIN COLOR CIRCUIT
1 OEM Alarm
2 White Signal
3 PLUG ---
4 RED V IGN
5 BLACK GND
6 PLUG ---
7 PLUG ---
8 OEM Silence
Secondary DISPLAY
Turntable
or
Reel
Dual Amplifier
A Dual Current Amplifier should be used whenever two displays share a single 4-20 mA transducer.