Manual
24
Breathing Air
Red
Black
Red
12 VDC
Ground
Black
OEM Power Feed
manuals\digital\air_level\AM-wire.eps..100998
1
2
3
4
8
7
6
5
1 Alarm OUT (ground)
2 PSI IN (Pressure)
3 Sensor + 10 VDC
4 Power + 12 VDC
5 Ground
6NC
7NC
8 Alarm Silence (ground)
DTM06-08SA
0462-201-20141 20 Ga.
Wire Insertion View
Alarm OUT
PSI Signal
PSI Supply
Pressure Transducer
PIN COLOR
1 PLUG
2BLACK
3 RED
4 RED
5BLACK
6 PLUG
7 PLUG
8 PLUG
PIN COLOR
1 RED
2 BLACK
MANUALS\DIGITAL\AIR_LEFT\AM_HARN.AI
CONNECTOR
PROVIDED HARNESS
1.125"
1.425"
0.410"
RED
BLACK
The
Class1
breathing air gauge is easily wired into the apparatus using the supplied
installation kit that includes the necessary wiring harness and connectors.