Manual

15
Digital Speedometer calibration is performed with the vehicle speed stabilized at 40 M.P.H.
or (40 K.P.H. )
The calibration mode is entered by the use of a password.
There are two magnetic switches, one located at each side of the display.
These switches are activated with the use of a magnet. Switch activation is visually
confirmed by the lighting of the closest decimal point on the display.
Enter the switch sequence below to enter calibration mode.
L L L R R R
Left Switch Left Switch Left Switch Right Switch Right Switch Right Switch
If the password is correctly entered,
CAL
will be displayed for 1/2 second followed by
40
Maintain a constant speed of 40 for a minimum of 10 seconds to assure an accurate and
stable calibration before activating the left switch.
Activate the left switch.
The display will read
donE
and return to normal operation showing the current speed.
Calibration is now complete.
NOTE:CALIBRATION SHOULD BE PERFORMED BY A PERSON OTHER THAN THE
APPARATUS
DRIVER.
IT IS UNSAFE FOR A DRIVERS ATTENTION TO BE DIVERTED BY ANY TASK
OTHER
THAN THE SAFE OPERATION OF THE VEHICLE.
Calibration