PRODUCT
SENTRY PRESSURE GOVERNOR
BY AMS
6.5.5. Discharge Sensor Range
This menu item allows sets the proper pressure range for the discharge sensor to either 300 PSI or 600 PSI (2068
kPa or 4137 kPa, 20.68 Bar or 41.37 Bar). Enter the OEM 1 menu and select “Dis. Sens. Rng (PSI/kPa/Bar)” then
press the INCREASE or DECREASE buttons to change to the desired sensor range value. Press the SAVE button
to save the OEM 1 menu items and exit the menu.
6.5.6. Inhibit RPM Presets
This menu item allows enabling/disabling of the RPM mode preset usage when pump discharge pressure over 10
PSI is detected. Enter the OEM 1 menu and select “Dis. Sens. Rng (PSI/kPa/Bar)” then press the INCREASE or
DECREASE buttons to change to the value (NO or YES). Press the SAVE button to save the OEM 1 menu items
and exit the menu.
6.5.7. Warning Source
This menu item configures the coolant temperature and oil pressure warnings to be determined by the CAN Bus or
by user selected points. Enter the OEM 1 menu and select “Warning Source” then press the INCREASE or
DECREASE buttons to change to the value (BUS or USER). Press the SAVE button to save the OEM 1 menu
items and exit the menu.
6.5.8. Coolant Temperature Warning (USER)
This menu item configures the coolant temperature warning trip point. This value is only used if the Warning
Source is set to “USER”. Enter the OEM 1 menu and select “Cool Tmp Warn (Deg F/DegC)” then press the
INCREASE or DECREASE buttons to change to the warning temperature trip point. Press the SAVE button to
save the OEM 1 menu items and exit the menu.
6.5.9. Coolant Temperature Critical (USER)
This menu item configures the coolant temperature critical trip point. This value is only used if the Warning Source
is set to “USER”. Enter the OEM 1 menu and select “Cool Tmp Crit (Deg F/DegC)” then press the INCREASE or
DECREASE buttons to change to the critical temperature trip point. Press the SAVE button to save the OEM 1
menu items and exit the menu.
6.5.10. Oil Pressure Warning (USER)
This menu item configures the oil pressure warning trip point. This value is only used if the Warning Source is set
to “USER”. Enter the OEM 1 menu and select “Oil Press Warn (PSI/kPa/Bar)” then press the INCREASE or
DECREASE buttons to change to the warning pressure trip point. Press the SAVE button to save the OEM 1 menu
items and exit the menu.
6.5.11. Oil Pressure Critical (USER)
This menu item configures the oil pressure critical trip point. This value is only used if the Warning Source is set to
“USER”. Enter the OEM 1 menu and select “Oil Press Crit (PSI/kPa/Bar)” then press the INCREASE or
DECREASE buttons to change to the critical pressure trip point. Press the SAVE button to save the OEM 1 menu
items and exit the menu.
6.5.12. Intake Threshold
This menu item configures the intake threshold trip point which establishes when the Sentry determines static or
positive intake pressure operation. Enter the OEM 1 menu and select “Intake Threshold, (PSI/kPa/Bar)” then press
the INCREASE or DECREASE buttons to change to the intake threshold trip point. Press the SAVE button to save
the OEM 1 menu items and exit the menu.