Owner's manual
FORM-ENG-0018 REV A 05-27-03
607 NW 27th Ave
Ocala, FL 34475
Ph: 352-629-5020 or 1-800-533-3569
Fax : 352-629-2902 or 1-800-520-3473
TECHNICAL DATA SHEET
PAGE
22 OF 36
DATE
6/19/2014
PRODUCT GROUP
THROTTLE CONTROL
P/N 3045-101-00-CL1, 3045-102-00-CL1 REV
1.02
PRODUCT
SENTRY PRESSURE GOVERNOR
BY AMS
Defaults:
Unit of measure = PSI, °F First mode = Pressure Idle speed = 700 RPM
Preset RPM 1 = 1000 Intake sensor range = 300 PSI Maximum speed = 2400 RPM
Preset pressure 1 = 100 Discharge sensor range = 300 PSI Source ID = 7
Preset RPM 2 = 1000 Inhibit RPM presets = NO Pressure time out = 8 seconds
Preset pressure 2 = 100 Warning source = CAN Bus RPM mode gain = 750 RPM/v
Brightness day = 70 Coolant temp warning = 180 °F Pressure mode gain = 1 PSI
Brightness night = 50 Coolant temp critical =230 °F Dither enable = NO
Round pressure = YES Oil pressure warning = 40 PSI Pressure lag = 5 PSI
Day/night mode = DAY Oil pressure critical = 20 PSI BCM1 version = 1
Alert tone = ENABLE System voltage = 12 volts Scania mode = NORMAL
Pressure sensitivity = 5 PSI Engine control method = CFPG Twister rotation increase = CW
Intake pressure offset = 0 Control auto mode = Disabled Display Fuel Economy = YES
Discharge pressure offset = 0 Idle voltage = 0.5 volts Display Trans. Temp = YES
Display Oil Pressure = YES
USER menu OEM1 menu OEM2 menu FACTORY menu
6.3.5. Autoscale Analog Output
A SENTRY set to Analog control mode (see section 6.6.2) may use the Auto Scale configure method to
automatically set the IDLE voltage (see sections 6.3.5 and 6.6.4) and GAIN setting (6.6.9).
The engine must be running and the interlocks (as defined in section 4.3) must be enabled when running the Auto
Scale mode.
Enter the INFO menu and select “AutoScale Analog Output” then press the SAVE button. The display will prompt
you to verify that you want to set the Auto Scale the analog output. Press the green accept button to reset or the
red cancel button to not reset. If the engine control method is not set for “analog” a warning will be shown and Auto
Scale will not be attempted. Once back to the INFO menu you must press the SAVE button to save the Auto Scale
operation and exit the menu.
6.4. USER menu
The User Menu allows configuration of standard user modifiable items.
• Unit of measure
• Preset RPM 1
• Preset pressure 1
• Preset RPM 2
• Preset pressure 2
• Brightness, day
• Brightness, night
• Round pressure
• Display mode
Use the soft buttons to navigate and modify options.