REPORT No.:SZ21070039S02
Page 48 of 53
16.3. Repeated SAR Assessment
In accordance with published RF Exposure KDB procedure 865664 D01 SAR measurement 100
MHz to 6 GHz. These additional measurements are repeated after the completion of all
measurements requiring the same head or body tissue-equivalent medium in a frequency band. The
test device should be returned to ambient conditions (normal room temperature) with the battery fully
charged before it is re-mounted on the device holder for the repeated measurement(s) to minimize
any unexpected variations in the repeated results.
1. Repeated measurement is not required when the original highest measured SAR is < 0.80 W/kg;
2. When the original highest measured SAR is ≥ 0.80 W/kg, repeat that measurement once.
3. Perform a second repeated measurement only if the ratio of largest to smallest SAR for the
original and first repeated measurements is > 1.20 or when the original or repeated
measurement is
≥ 1.45 W/kg (~ 10% from the 1-g SAR limit).
4. Perform a third repeated measurement only if the original, first or second repeated measurement
is ≥1.5 W/kg and the ratio of largest to smallest SAR for the original, first and second repeated
measurements is > 1.20.