Product Info

MORLAB
Shenzhen Morlab Communications Technology Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
REPORT No.SZ21070039S02
Page 25 of 53
9. EUT Testing Position
This EUT was tested in six different positions. They are right cheek/right tilted/left cheek/left tilted for
head, Front/Back of the EUT with phantom 10 mm gap, as illustrated below, please refer to Appendix
B for the test setup photos.
9.1. SAR Evaluation near the Mouth/Jaw Regions of the Phantom
Antennas located near the bottom of a phone may require SAR measurements around the mouth and
jaw regions of the SAM head phantom. This typically applies to clam-shell style phones that are
generally longer in the unfolded normal use positions or to certain older style long rectangular
phones.
Under these circumstances, the following procedures apply, adopted from the FCC guidance on SAR
handsets document FCC KDB Publication 648474 D04v01r03. The SAR required in these regions of
SAM should be measured using a flat phantom. The phone should be positioned with a separation
distance of 4 mm between the ear reference point (ERP) and the outer surface of the flat phantom
shell. While maintaining this distance at the ERP location, the low (bottom) edge of the phone should
be lowered from the phantom to establish the same separation distance between the peak SAR
locations identified by the truncated partial SAR distribution measured with the SAM phantom. The
distance from the peak SAR location to the phone is determined by the straight line passing
perpendicularly through the phantom surface. When it is not feasible to maintain 4 mm separation at
the ERP while also establishing the required separation at the peak SAR location, the top edge of the
phone will be allowed to touch the phantom with a separation < 4 mm at the ERP. The phone should
not be tilted to the left or right while placed in this inclined position to the flat phantom.
9.2. Body-worn Configurations
The body-worn configurations shall be tested with the supplied accessories (belt-clips, holsters, etc.)
attached to the device in normal use configuration.
For body-worn and other configurations a flat phantom shall be used which is comprised of material
with electrical properties similar to the corresponding tissues.