REPORT No.SZ21070039S02
Page 21 of 53
Note: Please refer to the validation results for dielectric parameters of each frequency band.
The dielectric properties of the tissue simulating liquids were verified prior to the SAR evaluation
using a SPEAG Dielectric Assessment KIT and an Agilent Network Analyzer.
Table 1: Dielectric Performance of Tissue Simulating Liquid
Frequency
(MHz)
Tissue
Type
Liquid
Temp.( )
Conductivity
(σ)
Conductivity
Target (σ)
Delta (σ)
(%)
Limit
(%)
Date
2450 HSL 22.2 1.823 1.80 1.28 ±5 2021.07.28
5250 HSL 22.1 3.113 3.05 2.07 ±5 2021.08.01
5750 HSL 22.2 3.362 3.34 0.66 ±5 2021.08.03
Frequency
(MHz)
Tissue
Type
Liquid
Temp.( )
Permittivity
(εr)
Permittivity
Target (εr)
Delta (εr)
(%)
Limit
(%)
Date
2450 HSL 22.2 38.641 39.20 -1.43 ±5 2021.07.28
5250 HSL 22.1 37.251 37.70 -1.19 ±5 2021.08.01
5750 HSL 22.2 36.924 37.00 -0.21 ±5 2021.08.03