Product Info

MORLAB
Shenzhen Morlab Communications Technology Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555 Fax: 86-755-36698525
Http://www.morlab.cn E-mail: service@morlab.cn
REPORT No.SZ21070039S02
Page 20 of 53
7. Tissue Simulating Liquids
For SAR measurement of the field distribution inside the phantom, the phantom must be filled with
homogeneous tissue simulating liquid to a depth of at least 15cm.For head SAR testing, the liquid
height from the ear reference point (ERP) of the phantom to the liquid top surface is larger than
15cm. For body SAR testing, the liquid height from the center of the flat phantom to the liquid top
surface is larger than 15cm, which is shown in Fig. 7.1. For body SAR testing, the liquid height
from the center of the flat phantom to the liquid top surface is larger than 15 cm, which is shown
in Fig. 7.2.Thenominaldielectricvaluesofthe tissue simulating liquids in the phantom and the
tolerance of 5%are listed in below table.
The following table gives the recipes for tissue simulating liquids
Frequency
(MHz)
Water
(%)
Sugar
(%)
Cellulose
(%)
Salt
(%)
Preventol
(%)
DGBE
(%)
Conductivity
(σ)
Permittivity
(εr)
Head
750
41.1
57.0
0.2 1.4 0.2
0
0.89
41.9
835
40.3
57.9
0.2 1.4 0.2
0
0.90
41.5
1800,1900,2000
55.2
0 0
0.3
0
44.5 1.40
40.0
2450
55.0
0 0 0
0
45.0 1.80
39.2
2600
54.8
0 0
0.1
0
45.1 1.96
39.0
Body
750
51.7
47.2 0
0.9 0.1
0
0.96
55.5
835
50.8
48.2 0
0.9 0.1
0
0.97
55.2
1800,1900,2000
70.2
0 0
0.4
0
29.4 1.52
53.3
2450
68.6
0 0 0
0
31.4 1.95
52.7
2600
68.1
0 0
0.1
0
31.8 2.16
52.5
Simulating Liquid for 5GHz, Manufactured by SPEAG.
Ingredients (% by weight)
Water
64~78%
Mineral oil
11~18%
Emulsifiers 9~15%
Additives and Salt
2~3%
Fig 7.1 Photo of Liquid Height for Head SAR Fig 7.2 Photo of Liquid Height for Body SAR