REPORT No.SZ21070039S02
Page 18 of 53
6.9. Test Equipment List
Manufacturer Name of Equipment Type/Model
Serial
Number
Calibration
Last Cal. Due Date
SPEAG 2450MHz System Validation Kit D2450V2 805 2018.10.26 2021.10.25
SPEAG 5000MHz System Validation Kit D5GHzV2 1176 2018.11.06 2021.11.05
SPEAG
DOSIMETRIC ASSESSMENT
SYSTEM
DASY52 52.10.4.1527 NCR NCR
SPEAG Dosimetric E-Field Probe EX3DV4 3823 2021.01.22 2022.01.21
SPEAG Data Acquisition Electronics DAE4 480 2021.06.22 2022.06.21
SPEAG Dielectric Assessment KIT DAK-3.5 1279 2020.11.03 2021.11.02
SPEAG SAM Twin Phantom 2 QD 000 P40 CB TP-1464 NCR NCR
SPEAG Phone Positioner N/A N/A NCR NCR
R&S Network Emulator CMW500 165755 2021.02.25 2022.02.24
Agilent Network Analyzer E5071B MY42404762 2021.03.29 2022.03.28
mini-circuits Amplifier ZHL-42W+ 608501717 NCR NCR
mini-circuits Amplifier ZVE-8G+ 754401735 NCR NCR
Agilent Signal Generator N5182B MY53050509 2021.03.25 2022.03.24
Agilent Power Senor N8482A MY41090849 2020.10.19 2021.10.18
Agilent Power Meter E4416A MY45102093 2020.10.19 2021.10.18
Anritsu Power Sensor MA2411B N/A 2020.10.19 2021.10.18
Anritsu Power Meter NRVD 101066 2020.10.19 2021.10.18
Agilent Dual Directional Coupler 778D 50422 NA NA
MCL Attenuation1 351-218-010 N/A NA NA
KTJ Thermo meter TA298 N/A 2021.01.15 2022.01.14
N/A Tissue Simulating Liquids 600-10000MHz N/A 24H
Note:
1. The calibration certificate of DASY can be referred to appendix E of this report.
2. The Insertion Loss calibration of Dual Directional Coupler and Attenuator were characterized via
the network analyzer and compensated during system check.
3. The dielectric probe kit was calibrated via the network analyzer, with the specified procedure
(calibrated in pure water) and calibration kit (standard) short circuit, before the dielectric
measurement. The specific procedure and calibration kit are provided by Speag.
4. In system check we need to monitor the level on the power meter, and adjust the power amplifier
level to have precise power level to the dipole; the measured SAR will be normalized to 1W input
power according to the ratio of1W to the input power to the dipole. For system check, the
calibration of the power amplifier is deemed not critically required for correct measurement; the