Manual

THE CONTINUOUS POWER COMPANY
Page 15
SPECIFICATIONS
ELECTRICAL
Input
Voltage (Auto-selectable) 120VAC or 220VAC or
240VAC +10%, -20%
(without Battery discharge)
Power Factor Corrected IAW MIL STD. 1399 Sec. 300
Frequency 45 to 65Hz
Current See Model Selection Guide
Output
Voltage
120VAC ± 3%
Frequency 50Hz / 60Hz (software select)
Line Sync (software select)
Current See Model Selection Guide
Crest Factor Ratio
(Non-linear load and
less than 5% THD) Typical
@50% Load Up to 4.8:1
@75% Load Up to 3.2:1
@100% Load Up to 2.4:1
Total Harmonic Distortion (THD) 3% Typ; 5% Max.
(@100% Non-linear load)
Dynamic Response
±4% for 100% Step Load
Change,
0.5 Millisecond Recovery Time
Overload 110% for 10 Minutes;
200% for 0.5 Seconds
Efficiency (UPS) 88% Typ.
Battery Back-up See Model Selection Guide
UPS Protection Input and Output Short Circuit;
Input and Output Overload;
Excessive Battery Discharge
ENVIRONMENTAL
Operating Temperature 32
o
F to 104
o
F (0
o
C to 40
o
C)
Humidity 0% to 95% Non-condensing
Altitude Sea Level to 10,000 Feet
Audible Noise 39-42 dBA at Five Feet
MECHANICAL
Input Inlet (6’ Line Cord Provided) IEC 320
Output (Qty.) (6) NEMA Type 5-15R
Cooling Low Velocity, Temperature
Controlled Reversible Forced
Air
Dimensions See Model Selection Guide
Weight See Model Selection Guide
DESIGN
Standard Features Power Factor Corrected, Digital
Regenerative On-Line, Sinewave
Inverter Powers Load Continuously
Extended Brownout Protection
Designed for Non-linear Loads
Continuous Operation on
-20%,+12% Line
Automatic Bypass
RS232 Data Interface
Software Selectable Output
Frequency
AC Output Switch
Auxiliary Battery Connector
Optional SNMP Interface
Specifications UL Design
FCC Class A
IEEE 587/ANSI C62.41
MTBF In Excess of 100,000 Hours
Typical Recharge Time to
85% Capacity at 100% Load
8 Hours
CONTROLS AND INDICATORS
Visual Indicators
Sequenced LEDs
Single LED
Battery Level, Load Level
AC Input, Inverter On, Fault
Fault Silent, AC Output,
Cold Start, Replace Battery
Front Panel Controls Power On, Cold Start
Fault Silence, Battery Test
AC Output On/Off
Audible Alarms Utility Interrupt, Inverter Failure
Overload, Low Battery
RS232 Data Interface (DB-9F) Full Interactive, Remote Computer
Monitoring and Control of UPS
Functions.
Compatible with Systems
Enhancement UPS Monitor &
Control Software
Open-Collector (DB-9F) Allows Alarm Function Monitoring
Optional SNMP Interface
(RJ45)
Allows Full Control and Monitoring
Over Network Connection.
Specifications subject to change without notice. 7/99