Owner's manual

5
© Copyright 2014. All rights reserved.
SK2222

1. Submersible Turbine Efuent Pump - A submersible turbine
efuent pump is a multistage centrifugal design pump. Each stage
consists of an impeller and diffuser. Water pressure increases in
equal amounts as it passes from stage to stage. The more stages,
the higher the pressure the pump will develop.
To correctly select a pump for a specic application, the following
information must be known:
• The amount of discharge required in GPM or LPM
• The total dynamic head required in feet or meters
Use this information along with the performance data found on the
previous page to make your selection.
2. Controls - Submersible turbine efuent pumps require the use of
an above ground control panel or junction box with a pump control
switch for proper operation. Operation of these pumps without a
control panel or junction box with a pump control switch can result in
failure of the pump and void the warranty. At least three elevations
must be determined to control a pump within a given tank or basin:
pump on level, pump off level and high water alarm level.
3. Piping - The submersible turbine efuent pump can be installed with
schedule 40 PVC pipe. The pipe size should be 1¼” diameter for
the 11 GPM to 27 GPM pump series and 2” diameter for the 35-85
GPM pump series.
General piping from the pump to a splitter, distribution box, drain
eld etc., should be the same diameter as stated above. For long
pipe runs consult friction loss tables for correct pipe sizing.
4. Check Valve - A check valve is required in all duplex systems. It is
also required when a large amount of efuent can backush into the
system causing rapid cycling of the pump.
A 1/8” weep hole must be drilled in the side of the discharge
head when using a check valve (see drawing below for drill
location).

Locked Fuse/Circuit Winding
Maximum Rotor KVA Breaker Amps Resistance
HP Volts Phase Hz S.F. Amps Watts Amps Code Std. Delay Line to Line
1/2 115 1 60 1.6 12 970 64.4 R 30 15 1.0 - 1.3
1/2 230 1 60 1.6 6 970 32.2 R 15 8 4.2 - 5.2
3/4 230 1 60 1.5 8 1325 40.7 N 20 10 3.0 - 3.6
1 230 1 60 1.4 10.4 1600 48.7 N 25 11 2.2 - 2.7
1 1/2 230 1 60 1.3 13.1 2250 56.8 L 35 15 1.5 - 1.9
2 230 1 60 1.25 Y 13.2 2650 51.0 G 30 15 1.6 - 2.3 M
B 11.9 5.2 - 7.15 S
R 2.6
3 230 1 60 1.15 Y 14.0 3650 82.0 G 45 20 .9 - 1.5 M
B 14.5 3.0 - 4.9 S
R 4.5
35-85 GPM MODELS
11-27 GPM MODELS