Pump Fed Application
For direct pump-fed installations, the 6000 Series Automatic Multizone Valve is directly connected to the discharge side of the pump and is cycled from
one zone to the next by turning the pump off and on. See the Active Zone Diagram below in Figure 1.
Technical Specications
Valve Top and Body Construction: Die cast
Valve Bottom Construction: ABS High strength plastic
Flow Range: 15-100 GPM
Inlet: Threaded 1½" NPT
Outlets: Allows for 1½" PVC pipe slip and glue connection
6400 Series 4 Outlet Valve
Flow (GPM) 15 20 30 40 50 60 70 80 90 100
PSI Loss 2.0 2.5 3.0 3.5 4.0 5.0 6.0 7.5 9.0 10.0
Flow Characteristics:
6600 Series 6 Outlet Valve
Flow (GPM) 15 20 30 40 50 60 70 80 90 100
PSI Loss 2.0 3.0 3.5 4.0 5.0 6.0 7.5 9.0 10.0 11.0
Parts List
Parts List
REF NO. DESCRIPTION PART NO.
1
4 Outlet valve top 153295
6 Outlet valve top 153296
2 Valve body seal 150495
3 Rubber ap disc 153268
4
Stem with .032 spring 153269
Stem with .028 spring 153270
5
Stem / disk assy. w/ .032 spring 019141
Stem / disk assy. w/ .028 spring 019142
6
4 Outlet valve bottom 153271
6 Outlet valve bottom 153272
7 Vacuum Breaker assy. 151258
8
Two zone, 4 outlet cam 019136
Three zone, 4 outlet cam 019137
Four zone, 4 outlet cam 019138
Five zone, 6 outlet cam 019139
Six zone, 6 outlet cam 019140
9
Valve bottom screws (6) (10-24 x
3/4 Phil Pan SS
153273
10
Valve top screws (8) (10-24 x 5/8
Stlt.phst SS
153274
11
Cam retaining screws (2) (6 x 1/2
Phil Pan SS)
153275
12 Valve bottom S.S Pin (¼" dia.) 153073
Figure 1