Installation Sheet

TOTAL MASSAGE BATHS
Total Massage units are a combination of whirlpool and air
massages. The top three controls on on the “Therapy Control
Center” operate the whirlpool and the bottom three controls
operate the air system. The whirlpool and air massages systems
may be used at the same time if desired. The air bath control
center is explained in the section above.
The whirlpool is controlled by a three button control.
1. The rst button switches the pump on or off. The other features
will not operate unless the pump is turned on.
2. The second button sets the power level of the pump. Holding the
button depressed will cycle the pump power from low to high in a
continuous cycle. When the desired level is reached, remove your
nger quickly from the button to maintain that power setting.
3. The third button is a three step wave action button:
a. Position #1 operates the pump at a steady ow.
b. Position #2 operates the pump at a quick wave action.
c.Position #3 operates the pump with a slower wave action.
THIS PRODUCT IS DESIGNED FOR RESIDENTIAL USE
AND USE BY HEALTHY INDIVIDUALS
Children should not be allowed to use these products without adult supervision. Pregnant women and those with heart
conditions or other conditions that limit normal physical activity should consult a doctor before use.
REPAIR PROCEDURES
Most minor scratches (up to 1/64” deep) and cigarette burns can be removed by sanding the area with #180 or #240 wet
or dry sand paper and progressing down to #600 or #1200 grit. Finally, apply light bufng compound and buff area with a
clean stitched cotton bufng pad or equivalent. Use an extra application of ne bufng compound if necessary.
For Cracks and Major surface damage, call our service line (800) 426-8964.
WHIRLPOOL TROUBLE SHOOTING
MOTOR WILL NOT START:
1. Check Circuit Breakers.
2. Check for incorrect or loose wire connections.
3. Make sure the correct power supply is being used.
4. Electronic On/Off switch should be in the “On” mode.
5. Make sure that the jets are fully opened and water is owing.
MOTOR OVERHEATING AND CYCLING ON AND OFF:
1. Check for incorrect or loose wire connections.
2. Check for low voltage supply (frequently caused by undersized wire).
3. Make sure the motor gets a fresh air supply and the vents are kept unclogged.
MOTOR MAKES HUMMING NOISE BUT WON’T START:
1. Open jets see “illustration I”
2. Make sure that the motor shaft turns free.
3. Check for jammed impeller or an obstruction on the (volute) casing.
4. Check for low voltage and undersize wire.
LOW WATER FLOW:
1. Check for clogged plumbing lines.
2. Check for low voltage.
WATER LEAKS:
1. Check compression ttings (union connectors) making sure they are properly aligned and secured. HAND TIGHTEN
ONLY. DO NOT USE ANY TOOLS.
2. Make sure the O-ring is properly seated and not damaged.
SAVE THESE INSTRUCTIONS
This product and its components are ETL listed and IAPMO approved
Blower
Speed
Wave
Jets Speed Wave
Switches the
jet-pump on or off
Adjusts the variable
water-flow of the jets
up or down
Switches from continuous
to wave action water-flow
Switches the
air-blower on or off
Adjusts the variable
air-flow of the blower
Switches from continuous
to wave action air-flow
Illustration K