Installation Sheet

UNPACKING THE UNIT
1. Inspect the carton.
2. If you note carton damage, take a picture if possible and contact the deliverer.
3. Immediately inspect the unit for damage even if there is no visible carton damage. Once the unit is installed and there
is surface damage visible, we will assume it was caused by the installer if you do not report it immediatly. Installers are
responsible for damage that occurs once the unit is placed in its assigned location.
4. Inspect the plumbing for any loose ttings.
5. On whirlpool units the unions on the suction and discharge sides of the pump have been marked to indicate the
alignment that was present at the factory water test. If these are not aligned, retighten and test for water tightness.
6. Remove all packaging material except for the protective plastic. It was placed on the tub at the factory to eliminate
abrasions from handling. It should only be removed at the nal clean up.
Electrical Requirements
1. ALL CONNECTIONS MUST
BE GFCI (Ground Fault Circuit
Interrupted) PROTECTED
2. Whirlpool, Air Baths, and Total
Massage units require dedicated
20 amp, 120 volt service.
3. You must provide a receptacle
with a 20 amp conguration.
4. See local codes for proper wire
size, if not specied, use #12
Copper only wire.
5. If you use an optional heater,
then it will require its own
dedicated 20 amp service.
6. Total Massage units require only one 20 amp service. However if a heater is
used then a second 20 amp service is required.
IN LINE HEATERS ALWAYS REQUIRE THEIR OWN DEDICATED
20 AMP, 120 VOLT, GFCI PROTECTED CIRCUIT.
IMPORTANT SAFETY INSTRUCTIONS:
WARNING! WHEN USING THIS PRODUCT, YOU SHOULD ALWAYS FOLLOW BASIC
PRECAUTIONS. READ AND FOLLOW ALL INSTRUCTIONS PERTAINING TO RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS
1.To install an inline heater, simply saw or cut out the center portion of the red heater blank at the breaking lines. The
threaded pieces should remain on both sides of the pipe section.
2. Insert the inline heater and tighten the unions of the inline heater to the remaining threaded portion of the heater blank.
• DANGER: To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all
times.
• Use this unit only for its intended purpose as described in this bulletin. Do not use attachments that are not
recommended by the manufacturer.
• Never drop or insert any objects into any openings.
• The unit must be connected to a circuit interrupter (GFCI). Such a circuit is provided by the installer and should be tested
on a routine basis. To test the GFCI push the test button. The GFCI should interrupt power. Push the RESET button.
Power should be restored. If the GFCI fails to operate in this manner, there is ground current owing, indicating the
possibility of an electrical shock. Do not use this unit. Disconnect the unit and have the problem corrected by a qualied
service representative before using.
• Traction enhanced-textured tub bottom must remain clean to minimize slippage.
• DANGER: RISK OF ELECTRICAL SHOCK. All pumps and heaters must be connected to a ground fault circuit
interrupter (GFCI) protected outlets. Standard Line Total Massage units can be operated on a single service. In line heater
must always be connected to a dedicated service.
PIGGY BLOWER
7.5 AMP
OUTPUT
INTPUT
UP/HAUT
W/D
KEYPAD
GROUND
TMS-VARIABLE
CONTROL
120V/20AMP
MALE PLUG
AIR MASSAGE CIRCUIT
Blower
Speed
Wave
Illustration B
HEATER
12.5 AMP
120V/20AMP
MALE PLUG
ON/OFF PUMP
8.8 AMP
OUTPUT INTPUT
UP/HAUT
W/D KEYPAD
TMS-P/TIMER
CONTROL
PUMP FLOW
CONTROL VALVE
0.5 AMP
PIGGY BLOWER
7.5 AMP
OUTPUT
INTPUT
UP/HAUT
W/D
KEYPAD
GROUN D
TMS-VARIABLE
CONTROL
JUNCTION BOX
120V/20AMP
MALE PLUG
TOTAL MASSAGE CIRCUIT WITH OPTIONAL WATER HEATING ELEMENT
OPTIONAL HEATING ELEMENT
OPTIONAL JUNCTION BOX, IF NOT
AVAILABLE USE TWO 20AMP
CONNECTIONS
Blower
Speed
Wave
Jets Speed Wave
Illustration C
HEATER
12.5 AMP
120V/20AMP
MALE PLUG
ON/OFF PUMP
8.8 AMP
120V/20AMP
MALE PLUG
WHIRLPOOL CIRCUIT WITH OPTIONAL WATER
HEATING ELEMENT
OPTIONAL HEATING ELEMENT
ON/OFF SWITCH
ON
OFF
Illustration A