DIRTY WATER PUMP MODEL No: PSV1A + PSV2A Part No: 7236035, 7236040 OPERATION & MAINTENANCE INSTRUCTIONS 0807
INTRODUCTION • Thank you for purchasing this CLARKE dirty water pump. • This pump is designed for pumping dirty water only, that is water containing solids in suspension. It is NOT designed for pumping slurry, sludge, mud or heavily polluted water, or any water containing chemicals or other acidic contaminants including salt water. GUARANTEE • This product is guaranteed against faulty manufacture for a period of 12 months. Please keep your receipt as proof of purchase.
SPECIFICATIONS PSV1A PSV2A Motor 230V 50Hz 1Ph. 230V 50Hz 1Ph. Motor Output 335 Watts 385 Watts Head Max 5.8 meters 7 meters Maximum Imersion Depth 8 meters 8 meters Max. Flow Rate 140 l/min 170 l/min Outlet Fittings 1 1/4” BSP Threaded 1 1/4” BSP Threaded Dimensions (L x W x H ) 150 x 197 x 280 mm 150 x 197 x 280 mm Duty Cycle S3 - 2 Hours* S3 - 2 Hours* Sand handling Capacity 30 g/m3 30 g/m3 Maximum Solid Body Diameter 30 mm 30 mm Part No.
FOR YOUR OWN SAFETY KEEP CHILDREN AWAY • Do not allow children to touch the pump, cables or connections. USE A RESIDUAL CURRENT DEVICE: • The pump must be connected to a high sensitivity residual current device (RCD) which has a tripping current of less than 30mA. STORAGE • When not in use, the pump should be stored in a dry, secure place out of the reach of children. WATER TEMPERATURE • Do not use the pump if the water is liable to freeze, as this can cause damage to the pump.
ELECTRICAL CONNECTIONS Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.
RECOMMENDED USES The recommended uses for this pump are: • Drainage after flooding • The transfer of liquids • Drainage of containers • Taking water from wells and shafts Liquids that CAN be pumped: • Dirty water - That is water containing solids in suspension, • Swimming pool water Note: After pumping chlorinated water or other liquids containing additives, the pump should be rinsed with clean water.
PARTS IDENTIFICATION Handle Pump Base Float Switch May be supplied fitted to the pump 1/2” 3/4” 1” Elbow Multi Hose Adaptor 7
PREPARATION CONNECTING THE MULTI HOSE ADAPTOR WARNING! DISCONNECTED THE PUMP FROM THE MAINS POWER SUPPLY BEFORE CONNECTING THE MULTI HOSE ADAPTOR An Elbow is provided with a 1-1/4”BSP thread at either end as shown in the diagram opposite. Multi Hose Connector Ensure the end fitted with an O-Ring is screwed into the pump. Screwed on to the other end of the elbow, is a multi hose connector capable of accepting 1”, 3/4” or 1/2” hoses.
USING THE PUMP CAUTION! CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE PUMP IF IT IS DAMAGED IN ANY WAY 1 Place the pump on a flat surface in the area that you want to drain. • If there is sediment in the operating area, the pump should be placed on house bricks, or similar.
CLEANING AND MAINTENANCE WARNING! MAKE SURE THAT THE PUMP IS DISCONNECTED FROM THE MAINS SUPPLY BEFORE CLEANING, OR PERFORMING ANY MAINTENANCE. • These pumps should require no maintenance other than regular cleaning. If the pump starts to show signs of wear or damage, contact your CLARKE dealer for advice. • Do not attempt to repair the pump yourself, repairs must be carried out by your CLARKE dealer, or contact the CLARKE Service Department, on 020 8988 7400.
TROUBLE SHOOTING PROBLEM PROBABLE CAUSE Pump will not start. Water level too low - float switch in OFF position. Float switch may be jammed against side wall, or prevented from moving. Pump will start but not pump. Check that the base is not blocked. Discharge tube clogged or obstructed. The head may be too great, i.e. you are trying to lift the water too great a distance for the pump to cope with. (See specification chart page 3). Air lock in the pump, produced during the plunge.