Specifications

- 16 -
Unusual noise from
compressor.
Bolts loose.
Flywheel loose.
Unit installed on an unsuitable
base.
Bearings, piston rings or cylinder
worn.
Valve broken.
Compressor
becomes too hot.
Check, clean/replace.
Insufficient ventilation.
Oil level too low (check 2 or 3
times after stopping).
Fault in valves (machine not
stopping).
Not fully unloading
Non-return valve partly blocked.
Clean cooling fins and suction
filter.
Blown head gasket (machine
not stopping).
Dirt on cooling fins or suction
filter.
Unit working at too high a
pressure.
Reset to correct working pressure
detailed on unit.
Check pressure unloading genie,
adjust if necessary, check
valve(s).
Clean or that out non return
valve.
Connect to a supplementary
compressor or install a larger
model.
See that sufficient air is supplied to
flywheel or fan of compressor and
that hot air is properly vented.
Fill with oil – see Page 10.
Tighten bolts.
Tighten flywheel.
Move unit to a more solid base.
Check and replace gasket.
Replace worn parts or change
compressor pump.
Change valve parts.
Compressor being
overworked and running
continuously.